Multilayer Ceramic Capacitor / High Voltage X1Y2 AC Safety Capacitor
Features:
Capacitance range: 100pF~4700pF
Operating temperature range: -25 to +105 C
Working voltage: DC 1, 2,3, 6.3, 10 and 15kV
Operating temperature -25~125º C
Withstanding voltage: 1.5 times of working voltage 1kV <=UR <=10kVUT = 1. 5UR+500V,
UR <=10kV, UT = 1.5UR
Capacitance: measured at 20 +-2celium degree, with 5Vrms maximumClass I 1+-0.2MHz and class II 1+-0.2kHz
Capacitance tolerance: J: +-5%, K: +-10%, M: +-20% and Z: +80%-20%
Dissipation factor (DF): same condition as the capacitanceSL tgd <= 0.15%N3300 tgd <= 0.4%Y5P tgd <= 2.5%Z5U tgd <= 2.5%Z5V tgd <= 2.5%Bn tgd <= 0.5%Y5R tgd <= 0.35%
Insulation resistance (IR): with rated voltage 500V test 60 +-5secondsIR >= 10,000MQ
Temperature characteristic: SLN3300, Y5P, Z5U, Z5V and Y5R
SPECIFICATIONS:
|
Capacitance and Dissipation :
1.1 The capacitor is tested after be clamped with the test tool, can’t take the capacitor’ s noumenon for test with hand. Capacitance and dissipation factor are not exact because of temperature in hand and test result is not right.
1.2 The capacitor’s capacitance and Dissipation factor after voltage tested may not test before the capacitor is stored for 24 hours after voltage test. The capacitor must be discharge between leads before test, or else voltage of remainder attaint test apparatus.
2 Charge to capacitor after AC or DC Voltage, value, time and current are seted in test apparatus, clamping capacitor’s lead with clamp for test apparatus output. Space between clamps for test apparatus output must meet standardor else flashover will be happened between two leads if space is too small. Capacitor’s configuration was be destroyed if great current will be happened in capacitor for moment.
Contact Details:
Contact: Angel Sun
Tel: +86-13528847020
Email: Admin@winsunhk.cn
Skype: Angelsun618