Automatic Tracking Test Apparatus For Fire Resistance Test Equipments Asphalt Rutting Resistance Test
The IEC60112 Electrical Test Equipment Tracking Index Testing Apparatus(CTI)/Comparative Tracking Index Testing is used for electrical products under the influence of moisture and impurity environment. The electric leakage between different polar parts or between the live parts and the grounded metal parts may cause leakage of insulation, and the arc generated may cause breakdown of the electric appliance. Short circuit or material corrosion caused by discharge, and even ignition caused a fire. This test instrument is a destructive test for the insulation material to simulate the above conditions, to test and evaluate the relative tracking resistance of the insulator under the action of the electric field and the impurity-containing water under the specified voltage. The leakage tracking tester is suitable for electrical and electronic products, solid electrical insulation materials for household appliances and their products, such as relay sockets, transfer switch covers, contact body and so on.
5201A electric leakage mark tester
Model:5201A
Accord with standard:GB4207 IEC60112
Technology Data:
1.) controller:7 inch programmable controller
2.) electrical pressure display:digital voltmeter
3.) electrical current display:digital current meter
4.) dimensions:1120w*600d*1020h
5.) inner volume: ≥0.5cubic
6.) electrode material:platinum
7.) electrode size:2*5*35mm
8.) electrode pressure:1.00N
9.) electrode distance:4.0mm
10.) drop volume:50 drop/1cubic meter
11.) drop height:35mm (can be adjustable)
12.) drop time:30s+-0.1(can be setted)
13.) drop number:1~9999(can be setted)
14.) test voltage:50v~600v(can be adjustable)
15.) power supply voltage drop:1.0A+-0.1A<8%
16.) mark judgment:0.5A+-0.05A
Features:
1.) 7 inch touch screen control system
2.) digital display voltmeter
3.) digital display current meter
4.) imported micro drop pump
5.) liquid drop time and volume control precision
6.) test qualifid ,inqualified judgment function
7.) door open/close protect system
8.) overvoltage protect system
9.) full operation protect system
10.) tempered glass window
Main configure:
1.) standard electrode *1
2.) imported micro pump *1
3.) explosion prevent tempered glass *2
4.) standard liquid *1
5.) standard ruler *1
dimensions | 1120w*600d*1020h
|
inner volume | ≥0.5cubic |
electrode distance | 4.0mm |
test voltage | 50v~600v |