GB5455 ZY6014I Textile Flammability Testing Textile Vertical Flame Retardant Tester
Scope of application:
Fabric flame retarding performance measurement ── vertical method: specifies a test method for determination of various kinds of flame retardant treatment fabric flame retardant performance, can be used to determine the fabric tend to prevent burning and carbonization. Used for the determination of flame retardant, such as apparel fabric, decorative fabric and tent fabric.
Meet the standard:
In conformity with provisions of the GB5455 fabric flame retarding performance measurement ── vertical law standard;
Compliance with jis-1091 test standard.
Main parameters:
1. Combustion test box: 329x329x767mm, the top of the box is evenly arranged in diameter of 12. The 5mm does have six holes
2. Test clip: made of stainless steel, thick 2. 0mm, length 422mm, width 89mm
3. Power supply voltage and power: 220V plus or minus 10%, 50HZ, 100W;
4. Gas source: industrial methane gas or other fuel gas (e.g. household liquefied petroleum gas, natural gas, gas, etc.)
5. Igniter: the diameter of 11mm and the vertical line is 25 degrees
6. Timing device: combustion timing, stop ignition timing, 99. 99/h/m/s is accurate to 0. 01 h/m/s
7. Flow meter two
8. Heavy hammer: 54. 5 g113.4 g226.8 g340.2 g453. 6 g
9. Flame height: 40mm
10. Medical cotton wool.
11. Sample size: 300x80mm.
12. The laboratory burner is the Bunsen burner