Stainless Steel Wire Testing Equipment UL910 Standard Level For Combustion Test
Scope of application:
It is suitable for the test of cable and cable duct of CMP class. In the experiment, a number of samples were laid on the horizontal airway of the device, and 87.9KW gas Bunsen burner (30, 000BTU/HR) was burned for 20 minutes. Eligibility criteria for the flame shall not extend to 5 feet away from gas Bunsen flame front optical density peak of 0.5, the average density value maximum, 0.15 this CMP cable is usually installed in the ventilation duct or air handling equipment used in air circumfluence pressurization system, was approved by Canada and the United States.
Meet the standard:
Meet UL910 "Test Method for Fireand Smoke Characteristics of Electrical and Optical - Fiber Cables, informs the in Air Handling for Spaces trans porting environ getting Air" Test standard.
Main parameters:
Air intake chamber: composed of l-type galvanized steel components;
Inlet: 2 98.5*464 rectangular opening; Inlet baffle: automatic control and exhaust end are connected to a loop control.
The combustion chamber is 7.62 m long, the upper cover plate is 6.4m m, the inorganic reinforced cement plate is outside, the outer side is 51 mm insulation mineral, the upper side plate is sealed by the sink,
the observation window is high temperature resistant double glazing, and the observation port is 75*28 0mm.
Burner: as a dual port, elbow export of 19 mm, the distance from the center line of the burner to the centerline of nozzle is 102 mm,
the inner surface of the nozzle mouth to the upper cover plate is 1 September 1 mm, provide fire up, phagocytosis test of gas burner; Equipped with air flow meter and gas flow meter, gas regulating valve, gas stabilizer; Igniter, ignition for the electron.
Exhaust transition zone: consists of 304 # stainless steel, long * wide * height 902*686* 432mm.
Smoke measurement system: consists of the transmitting part and the receiving part. The distance between the light source and the receiver is 910mm
Data acquisition: the output signal of photoelectric tube is processed by microcomputer as continuous smoke screen recording, and the optical density and transmittance can be read directly.
Electric wire cable bracket: adopt the tensile strength 305Mpa cold rolled steel.
Oxygen analyzer: the imported paramagnetic oxygen analyzer is 0.1s
Anemometer: measurement accuracy is plus or minus 0.5m/s