Specifications
Brand Name :
YU YANG
Model Number :
YY0014
Certification :
CE
Place of Origin :
CHINA
MOQ :
1pcs
Price :
Negotiable
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
5 Pcs Per Month
Delivery Time :
7-30 Days
Packaging Details :
Wooden Box
Product Name :
Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale
Outside Dimensions :
1350×540×1480
Lamp power & length :
40W/Piece, 1200mm/Piece
Illumination and Condensation Cycle Mode :
Can be Independently Controlled or Alternately Cycled
Usage :
Universal Testing Machine, Textile Testing Instrument, Salt Spray tester, plastic and footwear tester, Temperature And Humidity Test
Center distance between the lamps :
70mm
OOperating Voltage :
220v
Safety Protection Devices :
Short - circuit Protection
Power :
Electronic, 380/ 220V AC±10% 50/60Hz, 14.5kW
Description

Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale

Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale

Description:

Our UV Aging Test Lamp is designed to evaluate the aging resistance of non - metallic materials under artificial light sources. It is ideal for materials used in the fitness equipment, playground equipment, and amusement park industries. Made with high - quality materials, this lamp can generate UV light to simulate the natural sunlight environment. It can cause the tested materials to show signs of damage, such as color change, cracking, and surface roughness, helping manufacturers enhance the quality and safety of their products.

Design criteria:

(1) ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings

(2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)

(3) ISO 4892-1: Plastics - Methods of Exposure to Laboratory Light Sources - Part 1: General guidance

(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps

(5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics

(6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure

Control System:

Uses a black aluminum plate for the connection with the temperature sensor, and a black - board temperature meter is applied for heating control to secure a more stable temperature environment. The radiometer probe is fixed steadily to avoid the frequent operations of installation and dismounting. The radiation amount is measured by a unique UV irradiometer that provides high - precision display and accurate measurement. The radiation intensity is maintained below 50W/m². Illumination and condensation can be controlled either independently or in an alternating, circular pattern.

Specifications:

Standard specimen size 75×290mm/24 pieces
Power 1 phase, 220V/50Hz /±10% 5KW
blackboard temperature range room temperature 30 ℃ ~ + 80 ℃
Irradiation black panel temperature 50℃~70℃
Material: Stainless Steel
Lifetime of lamp 1600Hours
Lamp power & length 40W/Piece, 1200mm/Piece

Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For SaleVoltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For SaleVoltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For SaleVoltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale

FAQ

1. How can I ensure the accuracy of test results in the ultraviolet aging test chamber?

Regular calibration of the chamber's components, such as the lamps, temperature, and humidity sensors, is essential. Use high - quality and properly characterized materials for testing. Follow standardized testing procedures and ensure that the test environment is consistent throughout the experiment. Also, keep records of all test parameters and any changes made during the testing process.

2. What maintenance tasks are required for the ultraviolet aging test chamber?** Regularly clean the interior of the chamber to remove any dust or debris that could affect the test results or the performance of the equipment. Check and maintain the ventilation and cooling systems to ensure proper operation. Inspect the lamps for any signs of damage or reduced output. Also, lubricate any moving parts as per the manufacturer's recommendations.

3. Can I customize the testing conditions in the ultraviolet aging test chamber?

Yes, many ultraviolet aging test chambers allow for customization of testing conditions. You can adjust parameters such as UV intensity, temperature, humidity, and the duration of the test according to your specific requirements. This flexibility enables more targeted and accurate testing of different materials and products. periods. Additionally, the test results may vary depending on the specific model and calibration of the chamber. prevent overheating and potential damage to the equipment.ely simple operation interfaces, it's still advisable to receive proper training. Understanding how to set the correct test parameters, handle the materials during testing, and interpret the results accurately is crucial. Specialized training can also help in troubleshooting common issues and ensuring the safe and efficient operation of the chamber.ound the world in the near future.

Send your message to this supplier
Send Now

Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale

Ask Latest Price
Brand Name :
YU YANG
Model Number :
YY0014
Certification :
CE
Place of Origin :
CHINA
MOQ :
1pcs
Price :
Negotiable
Contact Supplier
Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale
Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale
Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale
Voltage Ma Calibrator Digital Volt Ma Meter Loop Tester 0~24 Ma Ce Rohs For Sale

DONGGUAN YUYANG INSTRUMENT CO., LTD

Verified Supplier
8 Years
guangdong, dongguan
Since 2007
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
$ 1 Million-$ 2 Million
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement