Specifications
Brand Name :
YU YANG
Model Number :
YY0014
Certification :
CE
Place of Origin :
CHINA
MOQ :
1pcs
Price :
Negotiable
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
5 Pcs Per Month
Delivery Time :
7-30 Days
Packaging Details :
Wooden Box
Product Name :
Mufasha Digital Galvanizing Paint Coating Thickness Gauge Meter
Outside Dimensions :
1350×540×1480
Illumination and Condensation Cycle Mode :
Can be Independently Controlled or Alternately Cycled
Center distance between the lamps :
70mm
Temperature range :
RT+20℃~70℃
OOperating Voltage :
220v
Lamp power & length :
40W/Piece, 1200mm/Piece
Protection Level :
IPX4
Description

Mufasha Digital Galvanizing Paint Coating Thickness Gauge Meter

Mufasha Digital Galvanizing Paint Coating Thickness Gauge Meter

Description:

Our UV Aging Test Lamp is designed to conduct comprehensive aging tests on non - metallic materials. It is perfect for materials used in the furniture, sports equipment, and marine industries. The lamp is made of corrosion - resistant materials and can generate UV light to simulate real - world sunlight exposure. It can cause the tested materials to show signs of degradation, including color fading, cracking, and brittleness, allowing for a better understanding of the material's performance under outdoor conditions.

Design criteria:

(1) ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings

(2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)

(3) ISO 4892-1: Plastics - Methods of Exposure to Laboratory Light Sources - Part 1: General guidance

(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps

(5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics

(6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure

Control System:

Employs a black - hued aluminum plate to connect with the temperature sensor, and a black - board temperature gauge is used for heating regulation, thus ensuring a more stable temperature level.

The radiometer probe is firmly attached to avoid the repeated process of installation and disassembly. A special UV irradiometer with high - precision display and measurement features is used to

monitor the radiation quantity. The radiation intensity does not go beyond 50W/m². The illumination and condensation functions can be controlled separately or in an alternating, circular sequence.

Specifications:

Standard specimen size 75×290mm/24 pieces
Power 1 phase, 220V/50Hz /±10% 5KW
blackboard temperature range room temperature 30 ℃ ~ + 80 ℃
Irradiation black panel temperature 50℃~70℃
Material: Stainless Steel
Lifetime of lamp 1600Hours
Lamp power & length 40W/Piece, 1200mm/Piece

Mufasha Digital Galvanizing Paint Coating Thickness Gauge MeterMufasha Digital Galvanizing Paint Coating Thickness Gauge MeterMufasha Digital Galvanizing Paint Coating Thickness Gauge Meter

FAQ

1. What precautions should be taken when loading materials into the ultraviolet aging test chamber?*

First, ensure that the materials are clean and free from any contaminants that could affect the test results. Also, position the materials properly within the chamber to ensure uniform exposure to UV light. Avoid overcrowding the chamber, as this may lead to uneven aging. Additionally, use appropriate handling tools to prevent any damage to the materials during the loading process.

2. How does humidity affect the testing results in the ultraviolet aging test chamber?

Humidity plays an important role in the aging process. In combination with UV radiation, it can accelerate the degradation of materials, especially those sensitive to moisture. High humidity levels can cause swelling, corrosion, or chemical reactions in some materials. Therefore, accurately controlling and monitoring the humidity inside the chamber is essential for obtaining reliable test results.

3. Can the ultraviolet aging test chamber be used for long - term continuous testing?

Yes, it can be used for long - term continuous testing. However, during long - term operation, it's necessary to regularly check the performance of the chamber, including the lamps, temperature and humidity control systems. Also, ensure that the ventilation and cooling systems are functioning properly to prevent overheating and potential damage to the equipment.ely simple operation interfaces, it's still advisable to receive proper training. Understanding how to set the correct test parameters, handle the materials during testing, and interpret the results accurately is crucial. Specialized training can also help in troubleshooting common issues and ensuring the safe and efficient operation of the chamber.ound the world in the near future.

Send your message to this supplier
Send Now

Mufasha Digital Galvanizing Paint Coating Thickness Gauge Meter

Ask Latest Price
Brand Name :
YU YANG
Model Number :
YY0014
Certification :
CE
Place of Origin :
CHINA
MOQ :
1pcs
Price :
Negotiable
Contact Supplier
Mufasha Digital Galvanizing Paint Coating Thickness Gauge Meter
Mufasha Digital Galvanizing Paint Coating Thickness Gauge Meter
Mufasha Digital Galvanizing Paint Coating Thickness Gauge Meter
Mufasha Digital Galvanizing Paint Coating Thickness Gauge Meter

DONGGUAN YUYANG INSTRUMENT CO., LTD

Verified Supplier
8 Years
guangdong, dongguan
Since 2007
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
$ 1 Million-$ 2 Million
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement