Production Description:
Code Name
YJV
Rated Voltage (Uo/U)
0.6/1kV
Cable Structure
Copper Conductor/XLPE Insulation/PVC Sheath
CONSTRUCTION
Conductor
Number of conductors:1,2,3,4,5,3+1,4+1...
The conductors shall comply with the requirement given in IEC
Insulation
XLPE (Cross-linked Polyethylene) according to IEC
Sheath
PVC (Polyvinyl Chloride) according to IEC
CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 90℃
Max.short-circuit temperature
Maximum shall not exceed 250℃(5s Max,Duration)
Installation temperature
Ambient temperature under installation shall not be below 0℃
Minimum bending radius
The bending radius of cable: (D-Diameter of cable) ≥15D
TYPE & DESIGNATION OF BARE CONDUCTOR
Rated Voltage; (Uo/U)(Um) | 0.6/1kV |
Max. working; temperature | 70 °c for pvc; insulation and 90 °c for xlpe insulation |
Max. temperature; during short circuit (≤5S | 160°c (PVC; insulation), 250°c (XLPE insulation) |
Conductor | class 1 and 2 copper or aluminum |
Shape of conductor | circular and sectional |
Shape of conductor | circular and sectional |
Sectional area | 1.5 - 500mm2 |
Insulation | PVC / XLPE |
No. of cores | 1,2,3,4,5,6 |
Armour | steel wire or steel tape available |
Sheath | PVC |
Filler | Polypropylene lament with lapped binding tape |
Core-covering: | Binding tape |
Min. beding radius | 15 times cable radius (single core), 12 times cable radius (multi cores) |
Rated voltage: 0.6/1kV
Max. Conductor Temp.: normal (90℃), short circuit no more than 5 s (160℃ when section-area below 300mm2, 140℃ when section-area above 300mm2)
Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0℃
Min. Bending Radius: single core cable 20(d+D)±5%
Multi-core cable 15(d+D)±5%
Construction
![]() | 1. Conductor material: | Copper Core |
2. Sheath Material | PVC | |
3.Insulation Material | XLPE | |
4.Filler | Polypropylene lament with lapped binding tape | |
5.Armoured | unarmoured |
1. Stranded copper conductor class 2
2. XLPE insulation
3. PP Filling
4. Non-woven fabrics wrapping
5. PVC outer sheath
APPLICATION
YJV-Copper Conductor XLPE Insulated PVC Sheathed Power&Mains Cable.
Copper Conductor XLPE PVC LSZH Cable is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 0.6/1kV.
CABLE STANDARDS
GB/T12706-2008,IEC,BS,VDE,ASTM and etc. upon request.
8. Product Image
Company Contact Information:
OUR SERVICE | ![]() |
To provide quality products and excellent service are our missions. OEM and ODM are welcome. Above we provide a wide range of products’ information, any further information you need please contact us as below: Our entire team can serve you and look forward to working with you. | Shenzhen Jinhuanyu Wire and Cable Co., Ltd.
|