Specifications
Brand Name :
Kacise
Model Number :
KLD802
Place of Origin :
China
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
100+
Delivery Time :
5-8 work days
Packaging Details :
carton
Certification :
certificate of explosion-proof, CE
Medium :
non-corrosive liquid, slightly corrosive liquid
Measuring range :
0.1m~10/20/30/60/100m
Process connection :
flange ≥ DN80
Process temperature :
-40~110℃
Process pressure :
-0.1~1.6MPa
Antenna size :
32mm lens antenna
Antenna material :
PTFE/overall filling
Accuracy :
±1mm/±5mm
Protection class :
IP67
Center frequency :
80GHz
Launch angle :
Power supply :
DC24V/DC12~24V /AC220V
Casing :
aluminum / plastic / stainless steel
Signal output :
4...20mA/HART protocol/RS485 Modbus
Description

KLD802 80G FM Radar Level Sensor

Introduction

Level in the focus
KLD802 operates with a transmission frequency of 80 GHz. With an 80-mm antenna, this results in a beam angle of only 3°. The radar sensor receives only distinct, definitive reflections from the product surface. This makes the measurement more accurate and reliable.

Previous radar sensors required process fittings with a minimum size of 1½" to achieve adequate signal focusing. For that reason it was virtually impossible to use radar sensors on very small containers with their typically small mounting sockets. KLD802 operates with a transmission frequency of 80 GHz. This corresponds to a factor of 3 compared to the technologies used until now. For that reason, the antenna system and the process fitting can have correspondingly smaller dimensions.

Feature

  • Non-contact measurement with FMCW working principle;
  • The beam angle is small and it is more easier for the instrument to avoid interferencefrom a possible obstacle;
  • The radar's antenna size is small, and it is easy to be installed;The upper dead zone is smaller, it is more suitable for the River Water Monitoring;

KLD802

KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,

Medium: non-corrosive liquid, slightly corrosive liquid
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN80
Process temperature: -40~110℃
Process pressure: -0.1~1.6MPa
Antenna size: 32mm lens antenna
Antenna material: PTFE
Accuracy: ±1mm (range below 35m)
±5mm (range between 35m and 100m)
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/sainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire / 4...20mA/ RS485 Modbus

Installation

1.Flange Installation
When using flange installation, the minimum distance between the instrument and the tank wall should be 200mm.
datum plane
vessel center or axis of symmetry
KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,
2.Hoisting Installation
KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,

Installation Requirements

When installing the instrument, avoid installing it above the material inlet, and try to avoid various objects that affect the signal, such as stirring paddles, etc.

KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,
KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,

Under extremely complex working conditions, the instrument can work normally if there is no obstacle in the area with a radius of 20cm centered on the installation point.

KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,

Installation connection diagram:

The maximum installation spool height H max depends on the installation spool diameter D and the size of the product launch angle.

Too long installation connection will affect the radar performance.

KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,

Dimensions

Casing Dimension
Unit in mm:

KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,

Production:

KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,

Xi'an Kacise Optronics Tech Co., Ltd considers itself a solution provider and manufacturer. We offer maximum flexibility and a cost-optimised offer for our OEM customers.
What we could provide:
The range includes customized shell version/color, thread type(G-Thread/NPT Thread), Customized Software, prints, manual and catalog. If you are interested in installing at your side, Radar Module is available for sure.

Send your message to this supplier
Send Now

KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency 80 GHz,the radar's antenna size is small,

Ask Latest Price
Brand Name :
Kacise
Model Number :
KLD802
Place of Origin :
China
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
100+
Contact Supplier
KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,
KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,
KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,
KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,
KLD802 PTFE Antenna Radar Level Sensor For Liquids Center frequency  80 GHz,the radar's antenna size is small,

Xi'an Kacise Optronics Co.,Ltd.

Verified Supplier
7 Years
Shaanxi
Since 2008
Business Type :
Manufacturer
Total Annual :
8000000-10000000
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement