Specifications
Brand Name :
Kacise
Model Number :
KUFF2000
Place of Origin :
China
MOQ :
1
Price :
304~318USD/pc
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
100+
Delivery Time :
5-8 work days
Packaging Details :
carton
Accuracy :
≤1%
Velocity Range :
0~±10m/s, Bi-directional measurement
Pipe Size :
DN32~DN6000
Temperature :
- 30~160℃
Type of Liquid :
Single liquid can transmit sound wave. such as water, sea water, sewage, oil, chemicals , alcohol, etc
Pipe Material :
Steel, Stainless steel, Cast iron, Copper, PVC, Aluminum, Glass steel, etc. Liner is allowed
Signal Output :
1 way 4-20mA output(impedance 0~1K, accuracy 0.1%) 1 way OCT pulse output( Pulse width 6 ~ 1000ms) 1 way relay output
Interface :
RS485, support MODBUS
Power Supply :
Default DC8~36V. AC85~264V, water proof power adapter is optional.
Description

KUF2000 Series Clamp On Ultrasonic Flow Meter

Introduction
KUF2000 series clamp on ultrasonic flow meter consists of the meter and clamp on sensor.
The clamp on ultrasonic flow meter is easy for installation, no need to cut off the pipe and water, no press loss. It support measuring online long-term. Wide range of liquid flow can be measured with the sensor clamped on the pipe.

Both the main unit and sensor of the KUFF2000 flow meter are fixed on the pipe. Default is IP65, IP68 is optional.

Clamp on sensors are installed on the pipe. Suitable for pipe sizes from DN32mm to DN6000mm.

KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe

Feature

High Accuracy 1%
Wide measuring range
Several types transducer for selection, pipe size from Dn32 to Dn1600
High Reliability
Adopt low voltage, multi-pulse technology to improve accuracy, operation life and reliability.
Strong Anti-interference
Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc.
Powerful Recording Function
Automatically record the following data:
1. The totalizer data of the last 512 days/128 months/10 years
2. The time and corresponding flow rate of the last 6 4 times of power on and off events
3. The working status of the last 32 days
Support Heat Measurement
Connect the temperature transducer ,can finish the heat/energy measurement

Working Condition

Main Unit Sensor
Protection IP65 IP68
Humidity ≤85%RH
Temperature -20~60℃ -30~160℃

Basic Parameters

Accuracy ≤1%
Velocity Range 0~±10m/s, Bi-directional measurement
Pipe Size DN32~DN6000
Temperature - 30~160℃
Type of Liquid Single liquid can transmit sound wave. such as water, sea water, sewage, oil, chemicals , alcohol, etc
Pipe Material Steel, Stainless steel, Cast iron, Copper, PVC, Aluminum, Glass steel, etc. Liner is allowed
Signal Output

1 way 4-20mA output(impedance 0~1K, accuracy 0.1%)

1 way OCT pulse output( Pulse width 6 ~ 1000ms)

1 way relay output

Signal Input 3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor.
Interface RS485, support MODBUS
Data Storage SD card regularly store the pre-set results (optional)
Power Supply DC8~36V or AC85~264V

Dimension

KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe

Standard Clamp On Sensor
  • Built-in magnet, easy to be absorbed on pipe
  • IP68
  • Measuring range: DN32~DN6000
  • Temperature range: - 30~90℃

KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe

Type Model Measuring Range Temperature Dimension
Small Size TS-2 DN32~DN100 - 30~90℃ 45×25×28mm
Middle Size TM-1 DN50~DN700 - 30~90℃ 64×39×44mm
Large Size TL-1 DN300~DN6000 - 30~90℃ 97×54×53mm

High Temperature Clamp On Sensor
  • Built-in magnet, easy to be absorbed on pipe
  • IP68
  • Measuring range: DN32~DN6000
  • Temperature range: - 30~160℃

KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe

Type Model Measuring Range Temperature Dimension
Small Size TS-2-HT DN32~DN100 - 30~160℃ 45×25×28mm
Middle Size TM-1-HT DN50~DN700 - 30~160℃ 64×39×44mm
Large Size TL-1-HT DN300~DN6000 - 30~160℃ 97×54×53mm

Mounting Bracket Clamp On Sensor

  • Improve installation efficiency and accuracy
  • IP68
  • Measuring range: DN32~DN700
  • Temperature range: - 40~160℃

KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe

Type Model Measuring Range Temperature Dimension
Standard Small Size Sensor HS DN32~DN100 - 40~90℃ 318×59×85mm
Standard Middle Size Sensor HM DN50~DN300 - 40~90℃ 568×59×85mm
Extended (bracket only) EB-1 >DN300 - 40~90℃ 88×59×49mm
High Temp. Small Size Sensor HS-HT DN32~DN100 - 40~160℃ 318×59×145mm
High Temp. Middle Size Sensor HM-HT DN50~DN300 - 40~160℃ 568×59×145mm
Extended (bracket only) EB-1-HT >DN300 - 40~160℃ 88×59×49mm

Ordering Information

KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe

Send your message to this supplier
Send Now

KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe

Ask Latest Price
Watch Video
Brand Name :
Kacise
Model Number :
KUFF2000
Place of Origin :
China
MOQ :
1
Price :
304~318USD/pc
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Supplier
video
KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe
KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe
KUFF2000 Clamp On Ultrasonic Flow Meter Main Unit And Sensor Fixed On Pipe

Xi'an Kacise Optronics Co.,Ltd.

Verified Supplier
7 Years
Shaanxi
Since 2008
Business Type :
Manufacturer
Total Annual :
8000000-10000000
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier