Materials of main parts and the nominal operating pressure
Shell and cover | cover plate | oval wheel | Rotary shaft | bushing | Nominal pressure(MPa) | |
LC-A | Cast steel | Cast iron | Cast iron,Stainless steel Alloy aluminum, engineering material | Stainless steel | Bronze(with oil) or rolling bearing | 1.6 |
LC-E | Cast steel | Cast iron | Under DN50 6.3 DN80-100 4.0 6.3 DN150-200 2.5 | |||
LC-B,C | Stainless steel | Stainless steel | Stainless steel | graphite,rolling bearing | 1.6,2.5 | |
Notes:1. 0Cr18Ni12Mo2Ti for type LC-C; 0Cr18Ni9Ti for type LC-B. 2. Flange is convex under 2.5MPa ,and roughness at 6.3 MPa;and both of the above at 4.0 MPa. |
2. Accuracy class class 0.5,class 0.2
3. Operating temperature: series LC-A(-20℃~+60℃),series LC-B,E,L(-41℃~+60℃)
60℃~200℃(with high temp. radiator installed)
4 Explosion-proof mark: ExiaⅡCT5, dⅡBT4
5. Flow range: unit: m3/h
Type | DN | Viscosity (mPa. s) | ||||||||
<0.3 | 0.3~0.8 | 0.8~2 | 2~200 | 200~1000
| 1000~2000
| |||||
LC-10 | 10
|
| 0.2-0.5
| 0.08-0.5 | 0.08-0.5 | 0.05-0.5
| 0.06-0.3 | 0.03-0.3
| 0.03-0.2
| |
LC-15 | 15
|
| 0.75-1. 5 | 0.3-1.5 | 0.3-1.5 | 0.15-1.5 0.3-3 | 0.2-1.0 | 0.1-1.05
| 0.07-0.75
| |
LC-20 | 20
|
| 1.5-3
| 1-3 | 0.5-3 | 0.5-3 | 0.3-3 1.5-15 | 0.4-2.1 | 0.2-2.1
| 0.15-1.5
|
LC-25 | 25
| 4-6
| 3-6
| 2-6 | 1-6 | 1-6 | 0.6-6 1.56-15 | 0.8-4.2 | 0.4-4.2
| 0.3-3
|
LC-40 | 40
| 9-15
| 7.5-15
| 5-15 | 2.5-15 | 2.5-15 | 1.5-15
| 2.1-10.5 | 1.0-10.5
| 0.7-7.5
|
LC-50 | 50
| 10-24
| 8-24
| 8-24 | 4.8-24 | 4.8-24 | 2.4-24
| 2.4-16.8 | 1.6-16.8
| 1.2-12
|
LC-B40,50 | 40,50 | 8-20 | 6-20 | 6-20 | 4-20 | 4-20 | 2-20 | 2.8-14 | 1.4-14 | 1.0-10 |
LC--65 | 65
| 27-40
| 20-40
| 15-40 | 8-40 | 8-40 | 4-40
| 5.6-28 | 2.8-28
| 2-20
|
LC-80 | 80
| 40-60
| 30-60
| 20-60 | 12-60 | 12-60 | 6-60
| 8.4-42 | 4.2-42
| 3-30
|
LC-100 | 100
| 67-100
| 50-100
| 34-100 | 20-100 | 20-100 | 10-100
| 14-70 | 6-70
| 5-50
|
LC-150 | 150
| 127-190 | 95-190
| 64-190 | 38-190 | 38-190 | 19-190
| 26.6-133 | 13.3-133
| 9.5-95
|
LC-200 | 200 | 227-340 | 170-340
| 114-340 | 56-340 | 56-340 | 34-340
| 47.6-238 | 23.8-238
| 17-170
|
Accuracy class | 0.5 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 | 0.5 |
Note: If the temperature of the metered liquid is higher than 80℃. the maximum flow fate will be 90% of the primary flow, and the minimum will be 120%.
Installation and Operation