Air Purifier lamps UV Disinfection Electronic Portable Lamp Sterilization Ultraviolet Germicidal Lamp Anti Virus UV lamp
Application
This UV lamp was designed and produced according to national standard GB19258-2012. Mainly use in home, school, hospital, restaurant etc. It was used for killing bacteria and viruses. 99.99% killing indoor bacteria, and viruses.
Attention: Due to the harm of ultraviolet to eyes, skin, scalp and other human organs, the appliance can not be used directly. It needs to be used in the place which can avoid the ultraviolet to get to people directly, or professional equipment with UV barrier, or in the unmanned space. It is strictly prohibited to use the appliance when the ultraviolet can get to people or animals directly. People shall not stay with the appliance in same room if the appliance is with ozone function. After using this appliance, the doors and windows shall be opened for ventilation.
Technical data and product size
Model | Rated Voltage | Rated Wattage | Rated Current | PF | Radiation | Weight |
KS60D17W-S018801 | 220/110V-50/60Hz | 60W | 0.43A | 0.62cosΦ | 235uW/cm2 | 3.3kg |
KS60D17Y-S028801 | 220/110V-50/60Hz | 60W | 0.43A | 0.62cosΦ | 235uW/cm2 | 3.3kg |
KS38D17W-S018801 | 220/110V-50/60Hz | 38W | 0.26A | 0.62cosΦ | 180uW/cm2 | 3.1kg |
KS38D17Y-S028801 | 220/110V-50/60Hz | 38W | 0.26A | 0.62cosΦ | 180uW/cm2 | 3.1kg |
Control Panel
Product appearance name
Main Components
This product includes UV lamp tube, ballast, and bracket, base etc. Long life time,high Ra, lumen output is stable, high efficient.
Installation method and precautions.
Usage (same with remote controller or the control panle)
1. After connecting the power supply, lamp will ring one time. Power indicator light.
2. ON/OFF is to turn on or off this lamp.
3. After turn on the products please set up 15/30/60 minutes for working time.
4. After set up the working time, push button “ON” lamp will start to work in seconds.
5. During work time, if push button ON or OFF, the lamp will stop working and come back to standby.
Maintain
1. UV lamp tube should be cleaned on time by professional worker.
2. Collision is not allowed during use and maintenance to avoid scratching the lamp tube.
3. Check the connection regularly to avoid affecting the power on performance.
4. If the product broken, it needs to be repaired by professional worker.
5. If need to change the lamp tube, please contact with manufacture to replace the same model lamp tube.
Storage environmental conditions
Temperature:-20℃ ~ + 40℃
Humidity:(ta=25℃) ≤ 90%