KLT900 online turbidity meter turbidity sensor water quality stainless steel probe Lightning proof
Production Introduction
Outlines that the TSS turbidity/suspended matter concentration meter is an on-line analytical instrument designed for measuring turbidity or suspended matter in municipal sewage or industrial wastewater treatment.The TSS turbidity/suspended matter concentration meter consists of a transmitter and a sensor.The sensor can be easily installed in a pool or in a natural water body.The TSS turbidity/suspended matter concentration meter automatically compensates for the interference caused by pollution.Bidirectional digital communication between the transducer and the transducer prevents signal attenuation and allows greater distance between the transducer and the transmitter.
Measuring principle
TSS turbidity/suspended matter concentration meter work principle as shown in figure 1-1, sensor transmitter to send the red outside light in transit after being measured the absorption and scattering of content, part of the scattering light to 135°direction of detector, part of the scattering light detector to 90°direction.The light intensity in the direction of 135°and 90°is related to the turbidity of the measured sewage to a certain extent, and the TURBidity of TSS is precisely based on this principle for measurement.
Turbidity meter size structure diagram
host size
sensor size
Turbidity meter technical parameters
Performance | value |
System | Menu-driven software, with multi-point calibration function and binding programming, can set the measurement range, relay and current output; |
Supply | AC220V (min85V- max265V) 50/60Hz |
Maximum power consumed | 15 VA |
Fuse | 2A /220VAC |
Range | 0~4000 NTU |
Measurement Unit | NTU and mg/L are available. |
Resolution Rate | 0.1NTU |
Accuracy | 2% of the measured value, within 10NTU the error is not greater than 1NTU. |
Display | The display screen is 192 × 64 pixels, which can display turbidity measurement value, current time, historical trend line, etc. |
Principle | infrared light scattering 90° and 135° |
Output | 1 channel 4~20mA current signal isolation output, maximum load 750 ohms; 1-channel RS232 and 1-channel RS485 digital output (optional); 3 alarm signal relays, capacity 220 VAC/ 2 A, output can be set by the user; |
Host:Material | ABS+PC |
Host:Protection Level | IP65 |
Sensor Material | 316L stainless steel |
Cable Length | Dedicated shield cable, standard 10 meters (extendable) |
Operating Temperature | 0-50℃ |
Pressure | 0.6MPa |
Calibrate | It has been calibrated before delivery and no calibration is needed on site |
Ordering Information Selection Table
Ordering Information Selection Table | ||
KXTX00 | PH/ORP analyzer | |
Power supply | DC24V | |
AC220V | ||
Cable length | 5m | |
10m | ||
15m | ||
20m | ||
Temperature compensation | Sensor without temperature compensation | |
Sensor with temperature compensation | ||
Signal output | Only 4-20mA | |
Only 485 | ||
Also with 4-20mA , 485 signal output | ||
Special custom signal | ||
KLT500-DC24V--5m-Sensor without temperature compensation-Only 485 | Low Turbidity host, with DC 24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication. |
Contact us
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
Abbreviations table
NTU
The unit of turbidity is "degree", which is equivalent to the degree of turbidity produced by 1L water containing 1mg SiO2 (or white clay, diatomite), which is 1 degree, or Jackson.Turbidity unit is JTU, 1JTU=1mg/L white clay suspension.
The turbidity shown by modern instruments is the unit of scattering turbidity NTU, also known as TU.1NTU= 1JTU.
Recently, it is considered internationally that the standard of turbidity prepared with ullotropin-hydrazine sulfate has good reproducibility and is chosen as the uniform standard of FTU.1FTU=1JTU.