The KUS550 Ultrasonic Level meter is a top-notch device. It has a range of 3m, allowing for effective level sensing. With both RS485 and Analog Outputs, it offers versatile connectivity options. Its low power consumption and IP68 grade make it suitable for various environments. Ideal for applications where accurate and reliable level detection is crucial.
Features
. Designed for outdoor or indoor environments
. High sensitivity
. Readings can occur up to every 50mS (20Hz) within 2meters
. Free run operation can continually measure and output ranger information
. 13-30 supply with very low average current draw
. 0-10V with RS485 interface.
. Sensor operates at 125KHz.
. Sensor beam angle is 7 degrees.
.The analogue output can be set between 0-10V can work with the switch output.
Parameters
General specifications
Model: KUS550 | |
Measuring range | 0.25m~3m (5m customizable)KUS550A 0.15m-0.6m(1m customizable)KUS550B; |
Blind spot | The dead zone of KUS550A is 0 ... 250 mm (within 250mm is unstable working zone, it is not recommended to work in this range); the dead zone of KUS550B is 0-150mm; |
Supply voltage | 3.3 ... 30 VDC, ripple 10 %SS |
Working current | ≤ 45 mA (fastest measurement speed), typical power consumption ≤ 10 mA; |
Output signal | 0-10V. 0-3V 0-5V /4-20mA/NPN/PNP/RS485 Analog output. |
Measurement accuracy | ≤1 %F.S. |
Temperature compensation | Yes |
Ranging resolution | 0.1mm; |
Working conditions
Working temperature | -40…85℃ (233...358K) |
Storage temperature | -40…85℃ (233...358K) |
Other instructions
Electrical connection | 5-core cable (analog output), 6-core cable (switch output) . |
Protection class | IP68 |
Shell material | PVC /PVDF/PTFE/ABS |
Electronic interface and signals definition
Analogue output type wiring diagram
.
Switch output type wiring diagram
Dimensions
KUS | Model | Output | Max range | Description |
550 | ||||
Customized | ||||
SW-1 | Switch Output,SW-1 for one switch output,SW-2 for 2 switch outputs | |||
mA | 3 wire 4-20mA output | |||
10V | Output is Vout 0-10V | |||
5V | Output is Vout 0-5V | |||
3V | Output is Vout 0-3V | |||
RS485 | Output is RS485 | |||
TTL | UART TTL output | |||
XX m | XX m is the maxim range can be detected, the max range is 5 meters. Default is 2.5m | |||
KUS | 550 | RS485 | 2m |