Specifications
Brand Name :
Kacise
Model Number :
KSS521
Place of Origin :
shanxi xi'an
MOQ :
1
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
1000 Pieces per Week
Delivery Time :
5 work days
Packaging Details :
each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Storage Temperature :
-20-80℃
Operating Temperature :
-20-60℃
Operating Humidity :
0-90%RH
Work Pressure :
0.8-1.2 atm
Supply Voltage :
12V
Maximum operating Current :
120mA
Detection range (customizable) :
1500ppm
Measurement Accuracy :
± 10ppm or ±5% truth value
T90 pipeline type :
5S
T90 pipeline type of diffusion :
30S
Repeatability of Zero :
Less than ±50ppm
Repeatability of Range :
Less than ±5%.
Life Span :
10 years
Description

KSS521 Infrared SF6 Gas Sensor Module

1. Overview

SF6 gas is widely used as an insulating medium and arc extinguishing gas in power equipment, especially in high-voltage circuit breakers, transformers, transformers, capacitors, arresters, fuses, etc. If leakage occurs, the pressure of the equipment is reduced and the insulation capacity is reduced; Pollute and destroy the atmospheric environment, increase the greenhouse effect; Accumulation in low-level spaces, resulting in accidents such as lack of oxygen in the brains of staff and even rapid asphyxiation; Under the influence of partial discharge, high temperature and other factors, SF6 gas will produce highly toxic decomposition substances such as SF4, SF2, SOF2, etc.

KSS521 is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of SF6 gas at 10.5um. KSS521 adopts MEMS light source, special structure optical cavity and dual-channel detector to realize space dual optical path reference compensation, and microprocessor for signal acquisition, processing and output. KSS521 is small in size, low power consumption, and has UART, 485 (Modbus RTU, Modbus ASCII, Modbus custom optional) and single-bus digital interface, providing digital calibration zero and sensitivity functions, and providing manual calibration zero function.

KSS521 can be widely used in SF6 gas leak detection and other occasions SF6 gas concentration analysis in the power industry.

2. Technical parameters

parameter symbol minimum Typical values maximum unit
Storage Temperature Tstg -20 - 80 °C
Operating Temperature TA -20 60 °C
Operating Humidity HA 0 90 % RH
Work Pressure PA 0.8 1.2 atm
Supply Voltage Vs 11 12 30 V
Maximum operating current Iavg 100 120 150 mA
Detection Range (customizable). Ra 1500 ppm
Measurement Accuracy Acurracy ± 10ppm or ±5% truth value %vol
T90 pipeline type Pump suction 5 second
diffusion 30 second
Repeatability zero Less than ±50 ppm
Range Less than ±5%.
Life Span 10 year

3.Structural Dimension Drawing

± 10ppm Gas Detector Sensor For SF6 Sulfur Hexafluoride

KSS521 diffusion (pumping compatible) block diagram

Pump suction type: length * width * height: 61mm * 40mm * 32mm

Diffusion type: length * width * height: 61mm * 40mm * 18mm

4.Installation Instructions

The sensor is mounted with a positioning hole spacing of 54 mand an aperture of 3.2 mm.

The wiring socket spacing is 2.54 m m.

5.Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, not more than 3 months is recommended.

Do not use the sensor for a long time in an environment with a high density of dust.

Please use the sensor within the range of the sensor's power supply.

6.Ordering Instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name 2) Sensor range 3) Sensor measurement accuracy and output mode, etc

For example, KSS521, SF6, 0-5000 ppm

7.Order Information

Order information sheet
KSS521 KSS521 infrared SF6 gas sensor module
xxxx The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000 Range 200ppm (default).
10000 Range 10000ppm
50000 Range 50000ppm
encode The reaction speed is divided into two types: fast and slow
S Slow (default).
Q fast
encode Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
Custom Confirm the baud rate before ordering
2400 2400bps baud rate
9600 9600bps baud rate
19200 19200bps baud rate
38400 38400bps baud rate (default)
encode Serial port protocol
Modbus-RTU Standard Modbus-RTU protocol (default).
Modbus-ASCII Standard Modbus-ASCII protocol
Modbus-Self Modbus private protocol
KSS521 -2000 -S -38400 -Modbus-RTU

8.Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

Appendix

Shorthand Full name
VOL 1% VOL refers to 1% of the volume of a particular gas in air.
PPM 1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2 Oxygen molecules
LCD LCD display
RS485 Asynchronous serial port 485
DC direct current
AC Communication
PVC polyvinyl chloride

Send your message to this supplier
Send Now

± 10ppm Gas Detector Sensor For SF6 Sulfur Hexafluoride

Ask Latest Price
Brand Name :
Kacise
Model Number :
KSS521
Place of Origin :
shanxi xi'an
MOQ :
1
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
1000 Pieces per Week
Contact Supplier
± 10ppm Gas Detector Sensor For SF6 Sulfur Hexafluoride
± 10ppm Gas Detector Sensor For SF6 Sulfur Hexafluoride

Xi'an Kacise Optronics Co.,Ltd.

Verified Supplier
7 Years
Shaanxi
Since 2008
Business Type :
Manufacturer
Total Annual :
8000000-10000000
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement