TDLAS200 Laser Methane Sensor
Introduction
The laser gas telemetry module is manufactured based on laser absorption spectroscopy technology. It emits a laser beam of a specific wavelength to detect whether there is a target gas in the optical path range of the laser, thereby obtaining the concentration of the target gas.
Features
Measuring Principle
"Methane molecules absorb light of a specific wavelength" --Molecular absorption spectrum
"The amount of light absorbed by a transparent medium (methane gas mass) is proportional to the thickness and concentration of the gas mass" --Beer-Lambert's law
According to the above physical principles, a beam of light of a specific wavelength can be used to penetrate the leaking methane gas mass. According to the degree of weakening of the beam, the concentration of methane in the gas mass can be measured, and it only responds to methane (unique selectivity).
Using a detection cell with multiple reflections and allowing the laser to repeatedly pass through the gas being measured can multiply the detection sensitivity.
Technical Parameters
Product model | TDLAS200 |
Detection object | Methane (CH4) |
Measurement principle | Laser absorption spectrum (TDLAS) |
Static detection limit | 0.5ppm@25℃10SPS (typical value, please contact us for details) |
Volume | 53ml |
Fastest response time | 0.1s |
Measurement range | 0~5000ppm |
Measurement deviation | 0-200ppm true value +/-2ppm 200-1000ppm true value +/-1% 1000-5000ppm true value +/-2% |
12hrs drift | +/-1.5ppm |
Operating temperature | -20~50℃ |
Power supply | 5-12VDC 1W (typical) 3W (maximum) |
Dimensions and weight | 115×59×38mm |
Gas interface | Pagoda direct M-5AU-4 |
Fastest response time | Detection time 0.1s |
*1 Please ensure that the power input voltage of the module is not less than 5V
*2 Pump selection recommendation <500ml/min
Dimensions of the detection module
Dimensions of the detection module host: 115×59×38mm (excluding cables and gas connectors)
It is recommended to add a 0.45um PTFE hydrophobic filter at the air inlet end; connect the air pump and silencer filter at the exhaust end.