The KUF100 ultrasonic flow meter works based on the time difference method. It transmits and receives ultrasonic signals in the fluid, and uses the difference in ultrasonic propagation time in the downstream and upstream directions to calculate the flow rate, thereby further obtaining the flow value. The advantage of this method is that it can accurately measure liquids containing suspended particles or bubbles and is not affected by the fluid conductivity.
Supported Pipe Materials | stainless steel, iron, brass, aluminum, PVC, PP, PVDF and other rigid plastic pipes |
Supported Liquid Medium | Water or other (single without solid particles and impurities) |
Supported Medium Temperature | 0-75°C (no freezing on the surface, high temp, version customizable) |
Default Low Flow Cutoff | 0.1m/s |
Display Method | 256*128 backlit LCD |
Response Time | 0.5~60s |
Accuracy Class | ±2%, up to ±1% after calibration |
Data Storage Period | 300 milliseconds |
Memory Backup | EEPROM (data storage length: more than 10 years, data read/write frequency: more than 1 million times) |
Power And I/O Connectors | M12 aviation plug |
Output | 4-20mA |
Communication | Modbus RS485 |
Optional Output | OCT (pulse output) / one relay alarm |
Power Supply | 10-24V VDC |
Electric Power | <3W |
Circuit Protection | Power reverse protection, power surge protection |
Each output short-circuit protection, each output surge protection | |
Protection Level | IP65 |
Ambient Temperature | -10 to 60°C (no freezing) |
Relative Humidity | 35 to 85% RH (non-condensing) |
Vibration Resistance | 10 to 55 Hz, double amplitude 1.5mm, 2 hours each for XYZ axes |
Impact Resistance | 100m/s2 16 ms pulse, X, Y, Z axis each 1000 times |
Meter Material | aluminum alloy, industrial plastic |
Cable Length | Standard 2 meters, (PT1000 standard 9 meters) |
Pipe diameter | Upper limit flow value ( L/min ) |
15 | 60 L/min |
20 | 100 L/min |
25 | 200 L/min |
32 | 300 L/min |
40 | 400 L/min |
50 | 600 L/min |
65 | 1000 L/min |
Tip: The inner diameter of the smallest measurable pipe section is greater than or equal to 12mm.
DN15-40
DN50-65
Code | Definition |
Pipe diameter: DN15-DN65mm | |
Range: 0.03m/s-10m/s | |
Accuracy: ±2% (1% after calibration) | |
Measurement medium: water/other (single without solid particles and impurities) | |
Power supply: 10~24VDC/1A | |
Sensor operating temperature: 0-115℃; | |
Other: 2 meters of cable as standard | |
Heat meter: with a pair of PT1000 temperature sensors; one end of the temperature sensor is on the meter, and the other end of the cable is standard 9m | |
Pipe Diameter | |
S | DN15-DN40 |
T | DN50-DN65 |
Meter Type | |
1 | Ultrasonic flow meter |
2 | Ultrasonic cold (heat) meter |
Sensor Type | |
C2 | 0-65°C |
C2U | 0-115°C |
Output (can choose two out of four) | |
A | 4-20mA |
M | Modbus |
O | OCT (Frequency) |
R | 1 Relay |
PT1000 Temperature Sensor Cable Length | |
P | Temperature sensor cable length at the other end 9m |
P(15) | Temperature sensor cable length at the other end 15m |
P(25) | Temperature sensor cable length at the other end 25m |
Example:
ultrasonic flowmeter, range DN15-DN40, temp. range 0-65℃, with 4-20mA and RS485 output, standard cable length 2m.
ultrasonic cold (hot) meter, range DN15-DN40, temp. range 0-115℃, with 4-20mA and RS485 output, standard cable length 2m; with a pair of PT1000 temperature sensors; one end of the temperature sensor is on the meter, and the other end of the cable is standard 9m
Appendix:KUF100 Clamp On Ultrasonic Flow Meter Datasheet_v1...