TDLAS200 Wide-Temperature Range Methane Gas Detection Module
1.Introduction
The KACISE TDLAS200 Wide-Temperature Range Methane Gas Detection Module is designed for reliable performance in extreme conditions, with an operating temperature range of -20~50℃. It offers a detection range of 0~5000ppm and a fast response time of 0.1 seconds, ensuring accurate methane monitoring. The module features a compact design and a digital interface for easy integration. KACISE combines advanced TDLAS technology with robust construction, making this module ideal for industrial and environmental applications requiring wide-temperature operation.
2.Features
3.Measuring Principle
"Methane molecules absorb light of a specific wavelength" --Molecular absorption spectrum
"The amount of light absorbed by a transparent medium (methane gas mass) is proportional to the thickness and concentration of the gas mass" --Beer-Lambert's law
According to the above physical principles, a beam of light of a specific wavelength can be used to penetrate the leaking methane gas mass. According to the degree of weakening of the beam, the concentration of methane in the gas mass can be measured, and it only responds to methane (unique selectivity).
Using a detection cell with multiple reflections and allowing the laser to repeatedly pass through the gas being measured can multiply the detection sensitivity.
Product model | TDLAS200 |
Detection object | Methane (CH4) |
Measurement principle | Laser absorption spectrum (TDLAS) |
Static detection limit | 0.5ppm@25℃10SPS (typical value, please contact us for details) |
Volume | 53ml |
Fastest response time | 0.1s |
Measurement range | 0~5000ppm |
Measurement deviation | 0-200ppm true value +/-2ppm 200-1000ppm true value +/-1% 1000-5000ppm true value +/-2% |
12hrs drift | +/-1.5ppm |
Operating temperature | -20~50℃ |
Power supply | 5-12VDC 1W (typical) 3W (maximum) |
Dimensions and weight | 115×59×38mm |
Gas interface | Pagoda direct M-5AU-4 |
Fastest response time | Detection time 0.1s |
*1 Please ensure that the power input voltage of the module is not less than 5V
*2 Pump selection recommendation <500ml/min
Dimensions of the detection module host: 115×59×38mm (excluding cables and gas connectors)