FM200 Pipe Network System: Guangzhou Manufacturer 120L Automatic Fire Extinguishing System Wholesale
Product Introduction of External Storage Pressure Heptafluoropropane Fire Extinguishing System:
(1) The main components of the external pressure storage seven gas propane fire extinguishing system
① Fire detection control unit. Including fire extinguishing controller, sound and light alarm box, emergency start/stop button, air release indicator light, nitrogen start bottle group, etc.
② External pressure storage seven gas propane fire extinguishing system unit. Including fire extinguishing agent storage steel cylinders, nitrogen driven steel cylinders, container valves, one-way pressure relief devices, liquid level gauges, nitrogen delivery pipeline components, connecting pipes, one-way valves, etc.
③ Distribution devices and pipelines. Including selection valves, pipe networks, nozzles, etc
(2) Application mode of external storage pressure type seven-gas propane fire extinguishing system
① Unit independent system
A set of external pressure storage FM200 HFC-227ea heptafluoropropane fire extinguishing agent supply source protects a protected area through fixed pipes and nozzles.
Schematic diagram of unit independent system
1. Gas fire extinguishing controller. 2. Sprinkler. 3. Fire detector (temperature sense). 4. Fire detector (smoke sense). 5. Deflation indicator light. 6. audible and visual alarm. 7. Emergency start-stop button. 8. Signal feedback device. 9. Select the valve. 10. Start the cylinder bracket. 11. Start the bottle group with nitrogen. 12. Steel cylinder bracket. 13. Collecting pipe. 14 Standby pressure FM200 heptafluoropropane fire extinguishing system unit. 15. Start the pipeline relief valve.16. Safety valve
The gas fire extinguishing system can be started in three ways: automatic start, manual control and mechanical emergency manual control:
Among them, automatic start:
When the gas fire extinguishing control panel is in automatic working state, when the smoke detector in the protection zone reports a fire alarm, the alarm control host sends the first fire alarm command to the gas fire extinguishing control panel through the control module in the automatic state. When the temperature sensor or another smoke detector in the protection zone reports a fire alarm, the alarm control host sends the second fire alarm command to the gas fire extinguishing control panel through the control module. The gas fire extinguishing enters a 30-second delay. After the delay, the control panel outputs an active signal to the start bottle group, releases the start gas to open the fire extinguishing agent bottle group and the selection valve, and the fire extinguishing agent enters the protection zone through the pipeline. The signal feedback device transmits the signal to the fire alarm system and the fire extinguishing control panel, and the control panel starts the release indicator light outside the protection zone.
Company introduction:
Guangzhou Rongan Fire Protection Equipment Co., Ltd. is a professional manufacturer of fire protection facilities integrating R&D, production, design and sales services. The company has experts from the national fire protection industry standards committee and a group of professional technical service teams with more than ten years of experience in the fire protection industry, and will spare no effort to provide you with the most intimate and professional comprehensive technical solutions for fire protection engineering products. "Rongxiao" series products produced by the company have passed the national compulsory product certification and the national fixed fire extinguishing system inspection center, with reliable quality and stable performance, and the factory has passed the ISO9001 quality system certification.
Frequently asked questions:
Q1: Are you a manufacturer or a trading company? A1: We are manufacturers.
Q2: How long is the delivery time? A2:10 days, which can be negotiated according to the quantity.
Q3: How to deal with the fault? A3: During the warranty period, we will provide you with a remote emergency plan during working hours. During the free maintenance period, the company will replace spare parts or complete machines that have failed due to defects or quality problems free of charge.