Water mist fire extinguishing device is non-toxic and harmless to personnel
Introduction
High-pressure water mist fire extinguishing system is suitable for extinguishing Class A, Class B, Class C and electrical fires. Due to its advanced fire extinguishing mechanism, its use is basically not limited by the location and can be used on land, sea and space. It is especially effective for local protection of high-risk occasions and protection of confined spaces. Such as: petrochemical industry, military equipment, coal industry, medicine, food processing industry, ancient buildings, archives, commercial and civil buildings, subways, tunnels, large transportation vehicles, surface ships, aerospace, electricity, electronics industry, fire brigade and forest police, etc.
It can also be used for cooling and environmental protection temperature control and dust reduction.
1.1 Main technical parameters of the system
Open water mist fire extinguishing device:
Serial number | System implementation standard | Model specification | Working pressure MPa | Rated flow L/min | Operating temperature range ℃ | Equipped power kW | Working voltage V | Working pressure range Mpa | Stable pressure range Mpa |
1 | GB1149-2014 | XSWBG 112/14 -RA | 14 | 112 | +4~50 | 32 | 380 | 10~14 | 0.8~1.2 |
2 | XSWBG 224/14 -RA | 224 | 62 | ||||||
3 | XSWBG 336/14 -RA | 336 | 92 | ||||||
4 | XSWBG 448/14 -RA | 448 | 122 | ||||||
5 | XSWBG 560/14 -RA | 560 | 152 | ||||||
6 | XSWBG 672/14 -RA | 672 | 182 | ||||||
7 | XSWBG 784/14 -RA | 784 | 212 |
Closed water mist fire extinguishing device:
Serial number | System implementation standard | Model specification | Working pressure MPa | Rated flow L/min | Operating temperature range ℃ | Equipped power kW | Working voltage V | Working pressure range Mpa | Stable pressure range Mpa |
1 | GB1149-2014 | XSWBGB 112/14 -RA | 14 | 112 | +4~50 | 32 | 380 | 10~14 | 0.8~1.2 |
2 | XSWBGB 224/14 -RA | 224 | 62 | ||||||
3 | XSWBGB 336/14 -RA | 336 | 92 | ||||||
4 | XSWBGB 448/14 -RA | 448 | 122 | ||||||
5 | XSWBGB 560/14 -RA | 560 | 152 | ||||||
6 | XSWBGB 672/14 -RA | 672 | 182 | ||||||
7 | XSWBGB 784/14 -RA | 784 |
212
|
Open water mist fire extinguishing device
Open water mist fire extinguishing device is divided into two types according to the application of the system: full flooding application and local application.
Open water mist fire extinguishing device model specifications: XSWBG 112/14-RA, XSWBG 224/14-RA, XSWBG 336/14-RA, XSWBG 448/14-RA, XSWBG 560/14-RA, XSWBG 672/14-RA, XSWBG 784/14-RA, a total of 7 models.
Open water mist fire extinguishing device dimensions
Model | L1(mm) | L2(mm) | H1(mm) | H2(mm) |
XSWBG 112/14-RA | 1920 | 780 | 1570 | 2000 |
XSWBG 224/14-RA | 2340 | |||
XSWBG 336/14-RA | ||||
XSWBG 448/14-RA | 2760 | |||
XSWBG 560/14-RA | ||||
XSWBG 672/14-RA | 3180 | |||
XSWBG 784/14-RA |
Closed water mist fire extinguishing device
The closed water mist fire extinguishing device is a wet system according to the application of the system.
Model specifications of closed water mist fire extinguishing device: XSWBGB 112/14-RA, XSWBGB 224/14-RA, XSWBGB 336/14-RA, XSWBGB 448/14-RA, XSWBGB 560/14-RA,
XSWBGB 672/14-RA, XSWBGB 784/14-RA, a total of 7 models.
Dimensions of closed water mist fire extinguishing device
Model | L1(mm) | L2(mm) | H1(mm) | H2(mm) |
XSWBGB 112/14-RA | 1920 | 780 | 1570 | 2000 |
XSWBGB 224/14-RA | 2340 | |||
XSWBGB 336/14-RA | ||||
XSWBGB 448/14-RA | 2760 | |||
XSWBGB 560/14-RA | ||||
XSWBGB 672/14-RA | 3180 | |||
XSWBGB 784/14-RA |