Heptafluoropropane Fm200 Extinguishing System GB25972-2010 Standard
Parameter:
No. | Specification | Technical Parameter |
1 | Filling pressure | 1.6Mpa |
2 | Spraying time | ≤8s |
3 | Working temperature | 0~50℃ |
4 | Starting mode | Electrical start |
Description:
1. Multiple management in the control of the whole system
2. Agent quantity for biggest zone is enough to protect all zones through selector valves
3. Direct target to expensive machine or delicate device
4. Short time discharge of extinguishing agent
5. Preparation for storage room
6. Space confirmation of placement for cylinder group
Applications:
Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.
The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement pro duction process of pulverized coal, and the ship's engine room, cargo hold, etc.
Competitive advantage:
1. Small but effective
2. Extremely simple installation
3. Little space for placement of it
4. Hanging on the ceiling or wall
5. Low cost for little protective zone
6. Colorless, tasteless and pure
7. Do no harm to environment
8. Easy transportation
Compositions:
Hanging type fm200 fire suppression device can be divided into two types: one is the electromagnetic type, the other is the temperature-controlled type.
The electromagnetic type hanging fm200 fire suppression device consists of a fm200 cylinder, a container valve, a solenoid actuator, a pressure switch, a stainless steel pipe, and a nozzle.
The temperature-controlled type hanging fm200 fire suppression system prefers a unit of temperature sensor instead of container valve and solenoid valve.
Attentions:
1/ One protected zone can just be equipped with one temperature-based hanging type fm200 fire suppression system.
2/ The temperature-based hanging type fm200 fire extinguisher doesn't need those electrical elements; The electromagnatic hanging type fm200 fire suppression system should be used together with electrical elements.
3/ Users should follow the routine check schedual that we provide.
4/ If there is any problem, we suggest that users shouldn't fix or touch anything. And the best method is to call and tell us the problem and then we send our professionals to fix it.