Description of Fire extinguishing agent
IG100 uses nitrogen with a 100% nitrogen content as the extinguishing agent in order to appropriately embrace the design concept of the new era fire extinguishing system. As a result, the product has features that effectively safeguard the environment and put out fires. It has the ability to protect the planet's ecological environment, provide clear and safe visibility, and stop pollution from fire fighting equipment. Nitrogen may be manufactured from a variety of sources and separated from air with low filling costs. The fire extinguishing system, which lowers the oxygen in the combustion zone, puts out fires via suffocation.
Parameters of Fire Suppression System
No. | Specification | Technical Parameter |
1 | Working Pressure | 15Mpa |
2 | Device Model | QMD15/80 | QMD15/90 |
3 | Capacity | 80Ltr | 90Ltr |
4 | Filling Capacity of Gas | 14.25kg | 16.04kg |
5 | Outside Diameter of Cylinder | Φ279mm | Φ325mm |
6 | Height of Cylinder | 1578+73mm | 1345+60mm |
7 | Spraying Time | ≤10s |
8 | Max Filling Rate | 0.178kg/L |
9 | Power | DC24V/1.6A |
10 | Nitrogen Pressure of Driving Device | 6.0±1.0Mpa(20℃) |
11 | Condition of Reserving Room for Container | temperature: 0~50℃ |
12 | Max Working Pressure | 17.2Mpa |
13 | Min Working Pressure | 13.6Mpa |
Application of Fire Suppression System
Fire suppression systems are designed to detect, contain, and extinguish fires in buildings, vehicles, and other enclosed spaces. Here are some common applications of fire suppression systems:
- Commercial Buildings: Fire suppression systems are commonly installed in commercial buildings such as offices, retail stores, and warehouses. These systems are designed to detect and suppress fires in their early stages, preventing them from spreading and causing extensive damage to property and equipment.
- Data Centers: Data centers house critical IT infrastructure, making them highly susceptible to fire-related disasters. Fire suppression systems with clean agents, such as FM-200 or Novec 1230, are commonly installed in data centers to protect sensitive electronic equipment from damage.
- Industrial Facilities: Industries such as chemical plants, refineries, and manufacturing facilities deal with hazardous materials that can easily catch fire. Fire suppression systems designed for these environments use specialized extinguishing agents that are effective against fires involving flammable liquids and gases.
- Marine Applications: Fire suppression systems are also commonly installed on ships and boats to protect against fires that can occur due to electrical faults, engine malfunctions, or other hazards. These systems use specialized agents that are safe to use in enclosed spaces such as engine rooms.
- Residential Homes: Residential fire suppression systems are becoming increasingly popular for homeowners who want to protect their families and property from fires. These systems are typically designed to detect and suppress fires in their early stages, preventing them from causing extensive damage.
In general, fire suppression systems are crucial for preventing the disastrous impacts of fires on people and property. To make sure they'll work in an emergency, they should be installed and maintained by trained experts. To achieve the highest level of safety, fire suppression systems should be utilized in conjunction with fire preventive strategies including routine fire drills, smoke detectors, and fire extinguishers.
Advantages
-
When compared to the standard 15MPa system, the number of fire extinguishing agent cylinders may be reduced by 25% to 50%.
- The building's between-cylinder space is successfully reduced, and its occupancy and utilization rates have both risen.
-
A constant 6MPa low pressure release can lower the cost of pipeline and pipe fittings.
- 6 MPa continuous release pressure, which provides longer-lasting and more effective pressure, may be transferred across a distance of 200 meters.
- With the release of the entire system under low pressure, the impact on employees at construction sites, machinery, and building structures will only be less and safety will rise.
- The external constant pressure reliever can only bear the pressure when the system is spraying, which is convenient for dis-assembly and maintenance and effectively reduces the failure rate of the system.
- After spraying, the system does not need to replace any parts, simple dis-assembly and secondary filling, the system can be quickly put into operation.
- The opening area of the pressure-relief device is reduced. the input cost of the pressure-relief device is directly reduced, and the safety buckle is installed and arranged more simply.
- Nitrogen fire extinguishing system(IG-100) can be widely used to make rapid response to fire, protect staffs on sites, sudden fire, important places sensitive to chemical reaction and effectively protect the safety of personnel and property.
- As a fire extinguishing agent, nitrogen is not a mixed product. It can be directly extracted from the air and has low maintenance and filling costs. Additionally, there are no chemical reagent residues that may exist in the mixed gas, making it safe and reliable. Due to filling an inert gas without the need for secondary pressurization, filling is simple and fast, which can shorten the production and processing cycle of the product.

Packages
We always place it into a wooden case after first packing it with polyfoam. At times, we will create a pallet for the goods in order to satisfy clients or meet safety requirements.

Mimic Diagram
Single/Multiple cylinder(s) for multiple zone

Single/Multiple cylinder(s) for one zone

After-Sale Service
• We have an efficient sales and after sales team to promise slove all client's question in time.
• We provide 8×6 hrs technical support and service.