Rigid Box Printing Quality Control Inspection Machine By Focusight
TECHNICAL SPECIFICATION
—FS500Gecko-P3A1N1
Product Name | Product Model | Paper Type |
Printing Quality Image Detection System V2.0 | FS500 Gecko-P3A1N1 | Gold, Silver & White Card |
Type | Classification | Description |
Box | 3 or more | Gray card & white card |
2.2 Machine configuration
Project Name | Configuration Instruction | No. | Functions Description | |
The Department of Detection & Measurement distribution series | Front printing variable code detection station | Exclusive German color C4kCCD camera | 1 |
|
Imported optical imaging lens | 1 | |||
Dedicated dome light source, length 525mm. | 1 | |||
High-speed image processing computer workstation (including high-speed image acquisition and processing card) | 1 | |||
Positive Pressing Varnish Inspection Station | US imported E2V high-speed 8K pixel line scan camera | 1 |
| |
Imported optical imaging lens | 1 | |||
Dedicated oblique light source, the length of 525mm | 1 | |||
High-speed image processing computer workstation (including high-speed image acquisition and processing card) | 1 | |||
Positive film embossing detection station | US imported E2V high-speed 8K pixel line scan camera | 1 |
| |
Imported optical imaging lens | 1 | |||
Dedicated reflective light source, the length of 570mm | 1 | |||
High-speed image processing computer workstation (including high-speed image acquisition and processing card) | 1 | |||
Reverse detection station | Import high-speed full-color 4kCCD camera | 1 |
| |
Imported optical imaging lens | 1 | |||
Special strip light source, length of 525mm. | 1 | |||
High-speed image processing computer workstation (including high-speed image acquisition and processing card) | 1 | |||
Surface array | Face array camera and lens | 1 |
| |
Special surface array light source | 1 | |||
Detect software configuration | Print Inspection Module for Visual Inspection Software FSCheck V2.0 | 1 | ||
Two - dimensional code detection module | 1 | Detection of re-code, error code, missing code and so on | ||
Defect Detection Statistical Report | 1 | Can be detected for the defect statistics type, data and other information | ||
Detection equipment | Printed special dust collector cabinet | 1 | Protection of detection devices from dust | |
Industrial refrigeration air conditioning | 2 | Protection of detection devices from process heat | ||
22 inch LCD monitor and keyboard and mouse | 1 | |||
Sound and light alarm device | 1 | Error code when the code re-alarm | ||
Mechanical platform configuration | Mechanical transmission platform structure configuration | Friction card issuer | 1 | |
On the suction style card structure | 1 | |||
Double-bit on the suction-style card structure | 1 | |||
Note: film and water-based varnish and other easy to scratch the sample is not within the scope of friction technology | ||||
Electrostatic ion blowing dust | 1 | Remove paper wool, to avoid false inspection | ||
Good product structure | 1 | RFish Scale Received ☐ Vertical Received Paper | ||
Scales turning waste collection point | 1 | |||
High-speed pneumatic reject mechanism | 1 | |||
Rear monitor | 1 | |||
Electrical supporting system | 1 | Standardize the operation | ||
Strong electric part of the mechanical platform | Germany SEW main motor | 1 | 4KW supply main drive power | |
Germany SEW feed motor | 1 | 1.5KW supply feeding cloth transmission power | ||
air pump | 1 | 2台4KW | ||
Good collection motor | 1 | 0.4KW | ||
Waste motor | 1 | 0.4KW | ||
Vibration motor | 1 | 0.04KW |
Note 1: The transmission system requires the user to provide the factory centralized gas source or external air compressor for the equipment to remove the waste.
2.3 Device function parameters
Project | Function parameters | |
Maximum detection speed | 220m/min 180m/min | |
Field of view | 500mm | |
Maximum paper size | Friction Feeder | 480mm(Width)* 420mm(Length) |
Suction Feeder | 480mm(Width)* 420mm(Length) | |
Minimum paper size | Friction Feeder | 90mm(Width)* 90mm(Length) |
Suction Feeder | 90mm(Width)* 120mm(Length) | |
Adapt to paper weight | 90~350g/㎡(paper weight > 195g) | |
Imaging accuracy (mm) | Direct Station Image Accuracy:0.12mm*0.12mm(4KCamera) Oblique Station Image Accuracy :0.06mm*0.12mm(8KCamera) Reflection Station image Accuracy:0.06mm*0.12mm(8KCamera) 220m/min Reverse Station Image Accuracy:0.13mm*0.24mm(4KCamera) Array Image Accuracy :0.067mm*0.067mm | |
Image Accuracy (mm) | Direct Station Image Accuracy:0.12mm*0.12mm(4KCamera) Oblique Station Image Accuracy :0.06mm*0.12mm(8KCamera) Reflection Station image Accuracy:0.06mm*0.12mm(8KCamera) 180m/min Reverse Station Image Accuracy:0.13mm*0.24mm(4KCamera) Array Image Accuracy :0.067mm*0.067mm | |
(Defect contrast of 40) defect detection routine |
| |
Bar Code Detection |
| |
Variable code detection (face array) |
Supports single and double line, alphanumeric or alphanumeric characters; |
2.4 Technical Parameters
Platform configuration description | Machine dimensions Long × high × width (mm) | Equipment area Length × width (mm) | Machine weight (tons) | Machine power KW |
Double station card + fish scale delivery | 6880×2300×3160 | 6900×3200 | 3 | 16 |
Mixed Feeder + fish scales delivery | 7980×2300×3430 | 8000×3500 | 3.3 | 17 |
Mixed Feeder + Vertical delivery | 7140×2300×3377 | 7200×3400 | 3.5 | 18 |
Accessories:
1. When unloading, first remove the equipment from the truck with a crane or forklift, then open the wooden box, and do not damage the cover;
2. When using the overall handling, please use 3 tons and more than 3 tons forklift;
3. When transferring parts, please use at least 2 tons and more than 2 tons forklift:
4. equipment around at least 500mm personnel passage way;
5. centralized air supply or external air compressor, trachea diameter at least 12mm, the output stability> 0.8Mpa pressure, 400mm width, 300g / ㎡ above the color box to be discarded output stability> 1Mpa pressure;
6. Machine with 3-phase 5-wire 380V / 50 / 60HZ power supply, the machine needs to ground, the total power of 15KW;
7. Line requirements: greater than or equal to 10 square millimeters copper core cable.
8. Use a circuit breaker greater than or equal to 60, and the inverter has high harmonics without the need for a secondary protector.
Pictures At Glance: