Non Contact Baby Forehead And Ear Thermometer Safe No Harm To Body
Feature
1. Multiple Function: 0-100℃(32-212℉) wide range, not only for body temperature,
but also for temperature of surface of the item like milk, food, bath water etc.
2. Quick and accurate: In just 1 seconds with±0.1℃(±0.1℉) precision.
3. Adjustable Setting for different operating conditions.
4. Automatic shut off: 15 seconds without operation.
5. Memorizes 32 groups of measuring datas.
6. Three colors backlight(color alarm):
Green: 34-37.3℃/ 93.2-99.1℉(Normal Temperature)
Yellow: 37.4-38.0℃/ 99.3-100.4℉(Slight Fever)
Red: 38.1-39.1℃/ 100.6-109.2℉(Fever)
Specification
S/N
|
Feature
|
Description
|
1
|
Product name
|
Baby Infrared Forehead Thermometer
|
3
|
Size:
|
153*41*44mm
|
4
|
Main Features
|
10 reading memory, dual scale, cpmpact ergonomic size, beeps when ready, jumbo display, replaceable battery, auto-off, 3 seconds reading
|
5
|
Measuring site
|
Forehead(Forehead Mode)
|
6
|
Measuring range
|
Forehead mode: 34.0℃~43.0℃(93.2℉~109.4℉)
Object mode: 0℃~100℃(32℉~212℉) Room temperature: 0℃~50℃(32℉~122℉) |
7
|
Reference body site:
|
Oral (This thermometer converts the ear temperature to display its "oral equivalent.")
|
8
|
Operation mode:
|
Forehead mode(Adjust mode)
|
9
|
Laboratory accuracy
|
Forehead mode:
±0.2℃ (0.4℉) during 35.5℃~42.0℃ (95.9℉~107.6℉) at 15℃~35℃ (59.0℉~95.0℉) operating temperature range ±0.3℃ (0.5℉) for other measuring and operating temperature range Object mode: ±4% or ±2℃(4℉) whichever is greater Room temperature: ±2℃(±4℉) |
10
|
Display resolution
|
0.1℃ or 0.1℉
|
11
|
Measure time
|
Approximately 3 second
|
12
|
Operating temperature
range: |
Forehead/Object mode:
10℃~40℃(50℉~104℉), 15%~85%RH, non-condensing Atmospheric Pressure : 700hPa ~ 1060hPa |
13
|
Storage and transport
temperature range |
-25℃~ 55℃ (-13℉~131℉), 15%~95%RH, non-condensing Atmospheric Pressure : 700hPa ~ 1060hPa
|
14
|
Warranty
|
2 year
|
15
|
Clinical accuracy
|
Clinical bias: -0.06℃(-0.1℉)
Clinical repeatability: 0.13℃(0.23℉) Limits of agreement: 0.85℃(1.53℉) |
Please pay attention during use
1. When measuring body temperature, the ambient temperature is preferably between 16 ℃ -35 ℃, lower or higher may affect the accuracy of the measurement.
2. A cold compress on the forehead of a fever patient, sweating and other cooling measures will make the measurement result lower, and measurement should be avoided in this case.
3. The environment around the person to be measured should be stable, and can not be measured in the air flow circle such as the fan, air outlet of the air conditioner.
4. Do not use the instrument outdoors or in a place with strong sunlight.
5. It is recommended to measure about 3 times each time, which is based on the most displayed data.
FAQ
Q: How to switch thermometer unit symbols between ℃ and ℉ ? .
A: When the thermometer is turned off, press and hold the scan key until the temperature unit symbol (℃ or ℉) appears on the screen,then you can switch thermometer unit symbols between ℃ and ℉ through click the scan key now..
Q: Need I debug the forehead thermometer before use?
A: No, the thermometer passed a rigorous calibration test before it leaves the factory, and the thermometer can automatically adapt to the ambient temperature and automatically debug it..
Q: What to do if I have a problem during using it.
A: Whenever you meet a problem during using our problem,you can ask our Customer Service for help.