Press Load Cell 20kg 50kg 100kg 200kg 500kg 1ton 2ton Push Force Load Cell
Flange to Flange Press Load Cell FFA is made of stainless steel utilizing strain gauge technology to deliver maximum 0.1% non-linearity of full scale.Pull And Push Force Sensor FFA offers 20kg / 50kg / 100kg / 200kg / 500kg / 1000kg / 2000kg seven rated load capacities to choose from, pull push force transducer FFA can be used for both tension and compression force measurement. Stainless steel construction, flange design, compact size, bidirectional force measurement, high accuracy, Push Force Load Cell FFA offers a perfect force measuring solution for applications such as wire tension control, force distribution analysis, automated control, cylinder thrust force measurement, assembly force monitoring, spring testing, ultrasonic welding clamp force control, hand press force verification, and so on. In addition to the standard specifications, Forsentek is also capable of and willing to provide custom design service to meet requirements of different applications.
Dimensions(Unit in "mm")
Ordering code | Measurement Range | Force direction |
FFA-200N | 0-200N / 0-20kgf | Tension/compression |
FFA-500N | 0-500N / 0-50kgf | |
FFA-1kN | 0-1000N / 0-100kgf | |
FFA-2kN | 0-2000N / 0-200kgf | |
FFA-5kN | 0-5000N / 0-500kgf | |
FFA-10kN | 0-10kN / 0-1000kgf | |
FFA-20kN | 0-20kN / 0-2000kgf |
Specifications
Capacity | 200N / 20kg / 45 lb 2000N / 200kg / 450lb 20kN / 2000kg / 4.5klb |
Rated output | 2.0 mV/V |
Excitation | 3-15V |
Zero balance | ±0.05mV/V |
Nonlinearity | ±0.1% of capacity |
Hysteresis | ±0.1% of capacity |
Nonrepeatability | ±0.05% of capacity |
Creep(5min) | ±0.05% of capacity |
Safe overload | 150% of capacity |
Ultimate overload | 200% of capacity |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.02% R.O./oC |
Temperature shift span | ±0.02% R.O./oC |
Input resistance | 385±30 ohms |
Output resistance | 350±10 ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP62 |
Material of element | Stainless steel |
Cable | Ø3*3000mm 4-core shielded |
Wiring code | Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
Instruction of load cell output:
Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output of pull push load cell FFA is around 2.0mV/V.
Power supply of flange type press force sensor FFA is normally within 3-15V.
Load / Capacity is within 0-1.
So the output range of push force transducer FFA is normally within -30mV...+30mV for tension and compression force measurement.
Example: Flange Mounted Push Load Cell FFA-5kN with 2.0mV/V sensitivity powered by 10V DC,the output range is -20mV...+20mV.
A load cell amplifier can be used to convert mV signal into -5-5V , 0-10V, 4-20mA.
Example: Press Load Cell FFA-10kN working with 0-10V amplifier,the Force-Voltage relationship will be 0-10kN compression load corresponds to 0-10V voltage output,which is linear regardless of the measurement error.
Press Load Cell 20kg 50kg 100kg 200kg 500kg 1ton 2ton Push Force Load Cell