Specifications
Brand Name :
Forsentek
Model Number :
FDNT
Place of Origin :
China
MOQ :
5pcs
Payment Terms :
T/T,Western Union or Paypal
Supply Ability :
4090pcs/month
Delivery Time :
3~25 working days
Packaging Details :
Carton
Usage :
Smart Inventory Management
Type :
Digital Load Cell
Capacity :
100kg 200kg 300kg 500kg
Structure :
Single Point Loadcell
Output :
RS485/RS232
Protocol :
Modbus RTU
Description

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output

Digital load cell FDNT utilizes a built-in microprocessor to convert mV signal from bonded wheatstone bridge into digital output,which makes load cell sensor FDNT more stable and accurate compared to analog load cells. Digital weight sensor FDNT supports RS485 Modbus RTU protocol with 0-100kg / 0-200kg / 0-300kg / 0-500kg four rated measuring ranges to choose from, it is corner trimmed for off-center load measurement with platform sizes up to 800x800mm, temperature compensation process guarantees stable readout in a wide temperature range. Typical applications of digital load cell transducer FDNT are for example smart shelves, vending machines, unmanned stores, intelligent warehouse management system and so on.

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output
Dimensions
Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output

Specifications

Rated capacity

100kg / 200kg / 300kg / 500kg
220lbs / 440lbf / 660lb / 1.1klb

Output

RS485/RS232 (Modbus RTU)

Excitation 5-12V DC
Nonlinearity ±0.02% R.O.
Hysteresis ±0.02% R.O.
Nonrepeatability ±0.01% R.O.
Creep(30min) ±0.02% R.O.
Safe overload 150% F.S.
Ultimate overload 200% F.S.
Compensated temperature 0...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.02% R.O./10oC
Temperature shift span ±0.02% R.O./10oC
Ingress protection IP65
Material of element Aluminum alloy
Cable Ø5*2000mm 4-wire shielded
Wiring code

Red--Power+
Black--Power-
Green--RS485 A
White--RS485 B

Parameters instruction:
Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.
Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.
Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.
Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.
Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.
Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output

A load cell (or loadcell) is a transducer which converts force into a measurable electrical output. Strain gauge based load cells are the most commonly used type and suitable for almost all industrial applications.Strain gauge load sensors contain wheatstone bridge within them to deliver mV output signal which is proportional to the applied load/force under constant power supply, thus the load/force can be measured by measuring the output signal from the transducer. Digital load cell FDNT outputs digital signal instead of analog signal through RS485 communication interface utilizing Modbus RTU protocol,the weight sensor was pre-calibrated before shipment and the weight value was trasmitted in hexadecimal, multiple digital load cells can be integrated together in one system,which makes digital weight transducer FDNT especially suitable for weight measurement where multiple loadcells are involved such as smart shelves,intelligent warehouse management,etc.

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS232/RS485 Output

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output

Click here to download datasheet

Send your message to this supplier
Send Now

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output

Ask Latest Price
Brand Name :
Forsentek
Model Number :
FDNT
Place of Origin :
China
MOQ :
5pcs
Payment Terms :
T/T,Western Union or Paypal
Supply Ability :
4090pcs/month
Contact Supplier
Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output
Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output
Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output
Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output
Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485/RS232 Output

Forsentek Co., Limited

Site Member
9 Years
guangdong, shenzhen
Since 2008
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
7000000-9000000
Employee Number :
100~150
Certification Level :
Site Member
Contact Supplier
Submit Requirement