Specifications
Brand Name :
Forsentek
Model Number :
FCRF
Place of Origin :
China
MOQ :
1pc
Payment Terms :
T/T,Western Union or Paypal
Supply Ability :
2080pcs/month
Delivery Time :
3~25 working days
Packaging Details :
Carton
Usage :
Compression force measurement
Type :
Column Load Cell
Output :
Analog
Capacity :
0-500ton(Selectable)
Structure :
Flange to flange
Description

Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN

High Capacity Flange Type Column Load Cell FCRF is made of alloy steel based on strain gauge technology adopting a column design that has a flange-to-flange mount for easy installation. High range Compression Force Sensor FCRF offers 0-300kN / 0-500kN / 0-600kN / 0-1000kN / 0-1500kN / 0-2000kN / 0-2500KN / 0-3000kN / 0-4000kN / 0-5000kN ten rated measuring ranges to choose from. You may find Cylinder tYPE Force Transducer FCRF applicable for pile load test, bridge load monitoring, injection molding machines, structure testing, rolling mills and so on.

Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN

Dimensions(Unit in "mm")

Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN

Specifications

Capacity

300kN / 30ton / 67 klb

500kN / 50 ton / 112klb

600kN / 60ton / 135 klb

1000kN / 100ton / 224 klb

1500kN / 150 ton / 337 klb

2000kN / 200 ton / 450klb

2500kN / 250ton / 562 klb

3000kN / 300 ton / 674 klb

4000kN / 400ton / 899 klb

5000kN / 500 ton / 1124 klb

Rated output 2.0 mV/V
Excitation 3-15V
Zero balance ±0.05mV/V
Nonlinearity ±0.3%-0.5% R.O.
Hysteresis ±0.3%-0.5% R.O.
Nonrepeatability ±0.2% R.O.
Creep(3min) ±0.1% R.O.
Safe overload 120% F.S.
Ultimate overload 150% F.S.
Compensated temperature -10...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.02% R.O./oC
Temperature shift span ±0.02% R.O./oC
Input resistance 780±50 ohms
Output resistance 750±50 ohms
Insulation resistance >5000M ohms
Ingress protection IP66
Material of element Alloy steel
Cable Ø5*5000mm 4-core shielded
Wiring code

Red--Excitation+ Black--Excitation-

Green--Signal+ White--Signal-

A Force Sensor is a transducer that converts mechanical load into mV signal proportional to the applied force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the load/force can be measured by measuring the output signal from the transducer which is normaly within -30mV...+30mV.A signal amplifier can be used to convert the mV signal into 0-5V / 0-10V / 4-20mA for further signal processing.

Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.
Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.
Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.
Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.
Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.
Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.
Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.
Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.
Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.
Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.
Input Resistance: The resistance of the load cell bridge circuit measured at the positive and negative excitation terminals with no load applied and with the output terminals open-circuited.
Output Resistance: The resistance of the transducer bridge circuit measured at the positive and negative signal terminals with no load applied and with the input terminals open-circuited.

Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN

Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN

Click here to download datasheet

Send your message to this supplier
Send Now

Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN

Ask Latest Price
Brand Name :
Forsentek
Model Number :
FCRF
Place of Origin :
China
MOQ :
1pc
Payment Terms :
T/T,Western Union or Paypal
Supply Ability :
2080pcs/month
Contact Supplier
Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN
Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN
Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN
Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN
Column Type Force Transducer 5000kN Cylinder Compression force Sensor 3000kN

Forsentek Co., Limited

Site Member
9 Years
guangdong, shenzhen
Since 2008
Business Type :
Manufacturer, Exporter, Trading Company
Total Annual :
7000000-9000000
Employee Number :
100~150
Certification Level :
Site Member
Contact Supplier
Submit Requirement