SI200 series frequency inverter has the following features:
Closed-Loop Vector Control ( +PG Card)
Robust design, high start torque
Can do big kilowatt ( around 1300KW)
Infenion Brand IGBT Inside Only
Total failure ratio <1%.
Built In MODBUS
Built In C3 EMC Filter
Basic principle
Si200 solar pumping system can provide water for remote areas lacking of electricity or places where the electricity supply is unstable. PV pump controller can convert the DC power from solar panels to AC power so to drive various kinds of pumps.System enables continiously pumping when in good weather. System is not equipped with strorage battery devices, it is suggested that pumping the water to conservation pool
for future use.Water source could come from river, lake,well,or other natural water source or special soucre.System enables application of floating switch in the conservation pool or water tower to control the operation of pumps. Low water level probes can be installed in the well to detect the water level of the well in order to stop the pumps when the well in low water level. Diagram 1 is a typical SI200 PV pumping
system. The main parts and compenents of this system is after diagram 1.
General Purpose Series & Off Grid Solar Pump Inverters & Elevator Inverters
FC280 & SI200 & FC280E
Diagram Wire
SI200 PV Pump Controller input/output parameter
SI200-2SXXX
Model | SI200-2S-0.7 | SI200-2S-1.5 | SI200-2S-2.2 |
PV array input parameter | |||
Max input voltage(V) | DC 450V | ||
Min input voltage(V) | DC 180V | ||
Recommended voltage(mpp) | DC 280~360V | ||
Recommended PV power(Kw) | 0.9 ~1.2 | 1.8~2.4 | 2.7~3.5 |
Spare AC generator | |||
Input voltage ( V ) | Singel phase AC 200-240(+10%) | ||
Max current(A) | 8.2 | 14 | 23 |
Generator capacity(kVA) | 1.5 | 3 | 4 |
Output parameter | |||
rated output voltage | 3-phase AC 200-240V | ||
Max current(A) | 4.7 | 7.5 | 10 |
Rated output power(kW) | 0.75 | 1.5 | 2.2 |
Output frequency | 0~50Hz/60Hz |
SI200-4TXXX Input/output parameter
Model | SI200-4T-2.2 | SI200-4T-3.7 | SI200-4T-5.5 | SI200-4T-7.5 | ||
PV array input parameter | ||||||
Max input voltage(V) | DC 800V | |||||
Min input voltage(V) | DC 350V | |||||
Recommended voltage(mpp) | DC 500~600V | |||||
Recommended PV power(Kw) | 2.7 ~3.5 | 4.8~6.4 | 6.6~8.8 | 9~12 | ||
Spare AC generator | ||||||
Input voltage ( V ) | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 5.8 | 10.5 | 14.6 | 20.5 | ||
Generator capacity(kVA) | 4 | 5.9 | 8.9 | 11 | ||
Output parameter | ||||||
rated output voltage | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 5.1 | 9 | 13 | 17 | ||
Rated output power(kW) | 2.2 | 3.7 | 5.5 | 7.5 | ||
Output frequency | 0~50Hz/60Hz | |||||
Model | SI200-4T-11 | SI200-4T-15 | SI200-4T-18.5 | SI200-4T-22 | ||||
PV array input parameter | ||||||||
Max input voltage(V) | DC 800V | |||||||
Min input voltage(V) | DC 350V | |||||||
Recommended voltage(mpp) | DC 500~600V | |||||||
Recommended PV power(Kw) | 13.2~17.6 | 18~24 | 22.2~29.6 | 26.4~35.2 | ||||
Spare AC generator | ||||||||
Input voltage ( V ) | 3-phase AC 380/400/415/440V(+15%) | |||||||
Max current(A) | 26 | 35 | 38.5 | 46.5 | ||||
Generator capacity(kVA) | 17 | 21 | 24 | 30 | ||||
Output parameter | ||||||||
rated output voltage | 3-phase AC 380/400/415/440V(+15%) | |||||||
Max current(A) | 25 | 32 | 37 | 45 | ||||
Rated output power(kW) | 11 | 15 | 18.5 | 22 | ||||
Output frequency | 0~50Hz/60Hz | |||||||
Model | SI200-4T-30 | SI200-4T-37 | SI200-4T-45 | SI200-4T-55 | ||
PV array input parameter | ||||||
Max input voltage(V) | DC 800V | |||||
Min input voltage(V) | DC 350V | |||||
Recommended voltage(mpp) | DC 500~600V | |||||
Recommended PV power(Kw) | 36~48 | 44~59.2 | 54~72 | 66~88 | ||
Spare AC generator | ||||||
Input voltage ( V ) | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 62 | 76 | 92 | 113 | ||
Generator capacity(kVA) | 40 | 57 | 69 | 85 | ||
Output parameter | ||||||
rated output voltage | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 60 | 75 | 91 | 112 | ||
Rated output power(kW) | 30 | 37 | 45 | 55 | ||
Output frequency | 0~50Hz/60Hz | |||||
Model | SI200-4T-75 | SI200-4T-90 | SI200-4T-110 | SI200-4T-132 | ||
PV array input parameter | ||||||
Max input voltage(V) | DC 800V | |||||
Min input voltage(V) | DC 350V | |||||
Recommended voltage(mpp) | DC 500~600V | |||||
Recommended PV power(Kw) | 90~120 | 44~59.2 | 132~176 | 159~211 | ||
Spare AC generator | ||||||
Input voltage ( V ) | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 157 | 180 | 214 | 256 | ||
Generator capacity(kVA) | 114 | 134 | 160 | 192 | ||
Output parameter | ||||||
rated output voltage | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 150 | 176 | 210 | 253 | ||
Rated output power(kW) | 75 | 90 | 110 | 132 | ||
Output frequency | 0~50Hz/60Hz | |||||
Model | SI200-4T-160 | SI200-4T-200 | SI200-4T-220 | SI200-4T-250 | ||
PV array input parameter | ||||||
Max input voltage(V) | DC 800V | |||||
Min input voltage(V) | DC 350V | |||||
Recommended voltage(mpp) | DC 500~600V | |||||
Recommended PV power(Kw) | 192~256 | 240~320 | 264~352 | 300~400 | ||
Spare AC generator | ||||||
Input voltage ( V ) | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 307 | 385 | 430 | 468 | ||
Generator capacity(kVA) | 231 | 250 | 280 | 355 | ||
Output parameter | ||||||
rated output voltage | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 304 | 377 | 426 | 465 | ||
Rated output power(kW) | 160 | 200 | 220 | 250 | ||
Output frequency | 0~50Hz/60Hz | |||||
Model | SI200-4T-280 | SI200-4T-315 | SI200-4T-355 | SI200-4T-400 | ||
PV array input parameter | ||||||
Max input voltage(V) | DC 800V | |||||
Min input voltage(V) | DC 350V | |||||
Recommended voltage(mpp) | DC 500~600V | |||||
Recommended PV power(Kw) | 192~256 | 240~320 | 264~352 | 300~400 | ||
Spare AC generator | ||||||
Input voltage ( V ) | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 525 | 590 | 665 | 785 | ||
Generator capacity(kVA) | 396 | 445 | 500 | 565 | ||
Output parameter | ||||||
rated output voltage | 3-phase AC 380/400/415/440V(+15%) | |||||
Max current(A) | 520 | 585 | 650 | 725 | ||
Rated output power(kW) | 280 | 315 | 355 | 400 | ||
Output frequency | 0~50Hz/60Hz | |||||
Model : ( Three-Phase 380V Range: -15%~20%)
Inverter Model | Capacity Power | Input Current | Output Current | Adoptable Motor |
FC280-4T-0.7G | 1.5KVA | 3.4A | 2.3A | 0.75KW |
FC280-4T-1.5G | 3.0 | 5.0 | 3.7 | 1.5 |
FC280-4T-2.2G | 4.0 | 5.8 | 5.1 | 2.2 |
FC280-4T-4.0G | 5.9 | 10.5 | 8.5 | 4.0 |
FC280-4T-5.5G | 8.9 | 14.6 | 13 | 5.5 |
FC280-4T-7.5G | 11 | 20.5 | 17 | 7.5 |
FC280-4T-11.0G | 17 | 26.0 | 25 | 11 |
FC280-4T-15G | 21 | 35.0 | 32 | 15 |
FC280-4T-18.5G | 24 | 38.5 | 37 | 18.5 |
FC280-4T-22G | 30 | 46.5 | 45 | 22 |
FC280-4T-30G | 40 | 62.5 | 60 | 30 |
FC280-4T-37G | 57 | 76.0 | 75 | 37 |
FC280-4T-45G | 69 | 92.0 | 91 | 45 |
FC280-4T-55G | 85 | 113 | 112 | 55 |
FC280-4T-75G | 114 | 157 | 150 | 75 |
FC280-4T-90G | 134 | 180 | 176 | 90 |
FC280-4T-110G | 160 | 214 | 210 | 110 |
FC280-4T-132G | 192 | 256 | 253 | 132 |
FC280-4T-160G | 231 | 307 | 304 | 160 |
FC280-4T-185G | 255 | 333 | 330 | 185 |
FC280-4T-200G | 287 | 380 | 377 | 200 |
FC280-4T-220G | 311 | 429 | 426 | 220 |
FC280-4T-250G | 355 | 470 | 465 | 250 |
FC280-4T-280G | 396 | 525 | 520 | 280 |
FC280-4T-315G | 439 | 605 | 600 | 315 |
FC280-4T-350G | 479 | 665 | 660 | 350 |
FC280-4T-400G | 530 | 730 | 725 | 400 |
FC280-4T-450G | 600 | 825 | 820 | 450 |
FC280-4T-500G | 660 | 910 | 900 | 500 |
Products Specifiction:
Basic Function | Specification |
Maximum output frequency | 0~600Hz |
Carrier frequency | 2.0kHz~10kHz;According to the load characteristics, carrier frequency can be adjusted automatically |
Input frequency resolution | Digital setting : 0.01Hz Analog setting : Maximum frequency x0.025% |
Control mode | 0:V/F 1:Vector mode 0 control |
Speed range | 1:50(Vector mode 0 ) 1Hz/150% rated torque |
Overload capability | G type:150% rated current for 60s; P type:110% rated current for 60s. |
Torque boost | Auto Torque boost Manual Torque boost ; 0.1%~20.0%. |
V/F curve | Four modes : Line , Multi-point , Square V/F curve,V/F separation |
Jog control | Jog frequency range:0.00Hz to F00.03(Max frequency) |
Accelerate/Decelerate curve | Line or S-curve Acc/Dec mode ,four kinds of Acc/Dec time Range of Acc/Dec Time0.0~6000.0s. |
DC brake | DC brake frequency : 0.00Hz to Maximum frequency brake time : 0.0 to 100.0s brake current value : 0.0 to 150% |
Simple PLC, Multi-speed | 16-speed operating through built-in PLC or control terminal |
Built-in PID | Close loop control system can be formed easily by using PID |
Automatic voltage regulating (AVR) | Output voltage is regulated when voltage of the power network changes |
Overvoltage and overcurrent stall control | During operation automatically limits the inverter output current and bus voltage, to prevent fan overcurrent and overvoltage trip. |
Rapid current limiting function | Minimizing flow failures, protect the normal operation of the inverter |
Instantaneous stop non-stop | Load feedback energy compensation voltage is reduced and continue to maintain a short time when change is momentarily interrupted. |
Speed tracking start | For high-speed rotation of the motor speed identification, impact- free smooth start |
Rapid current limit | Rapid software and hardware limiting technology to avoid frequent converter overcurrent fault. |
Virtual IO | Four sets of virtual DO,five sets of virtual DI, enables easy logic control. |
Timing Control | Timing control: set the time range 0.0Min~6500.0Min |
Multi-motor switch | Two independent motor parameters, enabling two motors switching control |
Bus Support | Two independent Modbus communication, Profibus-DP |
Motor overheating protection | Optional IO expansion card 1, analog input T_Motor(AI5) acceptable the input of motor temperature sensor .(PT100,PT1000) |
Command source | Given the control panel, control terminal, serial communication port given. It can be switched by a variety of ways. |
Torque boost | Auto Torque boost Manual Torque boost ; 0.1%~20.0%. |
Frequency source | Eleven kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways. |
Auxiliary frequency source | Eleven kinds of auxiliary frequency source. Flexible implementation of auxiliary frequency tuning, frequency synthesis. |
Input terminal | Standard: Six digital input terminals, one only supports 50khz high pulse input Three analog input terminals,two support -10V~10V voltage input One support 0 ~ 10V voltage input or 0 ~ 20mA current input Expansion capability: Two digital input terminals One analog input terminal, support -10V ~ 10V voltage input, and supports PT100 / PT1000 |
Output terminal | Standard: One high-speed pulse output terminal (optional open collector type), support of square wave 0 ~ 50kHz signal output One digital output terminal Two relay output terminals Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output Expansion capability: One digital output terminal One relay output terminal One analog output terminal, support 0 ~ 20mA current output or 0 ~ 10V voltage output |
Display and operation | |
LED display | Display parameters and status information |
The key lock and function selection | Achieve some or all of the keys locked, scope definition section keys to prevent misuse. |
Protection function | Input/output phase failure protection ,Overcurrent protection ;Over voltage protection; Undervoltage protection; Overheat protection ; Overload protection |
Options | Brake assembly, simple IO expansion cards, multi-IO expansion card |
Environment | |
Product tags
Low Frequency Solar Pump Inverter with Ce Certification, Solar Inverter Ask Latest Price
Brand Name :
FC & Janson Controls
Model Number :
FC280
Certification :
CE & ISO certificate
Place of Origin :
China
MOQ :
1pc
Price :
US$80/pc
Contact Supplier
Janson Controls Technologies (Shenzhen) Co.,Limited
Active Member
7
Years
guangdong, shenzhen
Since 2008
Business Type :
Manufacturer
Main Products :
Total Annual :
>20000000
Employee Number :
200~250
Certification Level :
Active Member
Discover similar products
View More
Find Similar Products By Category:
Contact Supplier
Submit Requirement
|