AC Drive Type Moving Walk Escalator 0.5m/s For Indoor Public Places
Standard Function:
Static electricity protection:Eliminate static electricity raised from running of steps
Emergency stop button:Push the emergency stop button to shop the escalator/moving walk against emergency raise
Skirting protection:Protection against risk of foreign bodies being jammed into clearance between steps and skirting.
Handrail entry safety protection:Protection against risk of foreign bodies being jammed into handrail entry
Main drive chains safety protection:Protection against risk of drive chains being breakage or undue elongation
Over-speed protection :Protection against risk of speed being over 20% of rated speed
Under-speed protection : Protection against risk of speed less than 80% of rated speed.
Un-intentional reversal protection :Protection against risk of unintentional reversal protection.
Lack of phase, error phase protection :Protection against risk of phase failure.
Short circuit protection:Protection against risk of short circuit.
Over-load protection: Protection against risk of motor continually over-load.
Step sagging protection: Protection against risk of steps being breakage and sagging.
Broken step chain protection :Protection against risk of step chains being breakage or under elongation.
Comb teeth safety protection :Protection against risk of foreign bodies being trapped at th point where the step enter the comb.
Handrail speed and broken handrail monitor:It detects the handrail speed and monitors the broken handrail.
Skirting anti-clamp device :It sets protection brush in the skirting on both sides of the step.
Step missing detection:It detects the step missing in the stairway.
The brake opens the monitor switch : It monitors whether the brake opens or not in during the escalator running.
Handwheel and handwheel protection cover open safety: During the use of handwheel, when open the handwheel and the handwheel protection cove
the safety switch will cut the safety circuit against escalator running.
Floor-plate monitor switch :When the pit cover plate opens, it cuts off safety circuit and stops the escalator safety switch.
Monitor of brake distance :It monitors brake distance of the escalator and auto-walk.
0 degree Moving Walk Construction Layout Drawing:
Pedal width | 1000 | 800 | |||
Quantity of cender support beam L4 | 6000 | 10000 | 6000 | 10000 | |
Support opposite force (KN) | R1 | 40 | 38 | 35 | 34 |
R2 | 34.5 | 34 | 32 | 31 | |
R3 | 62.5 | 78.5 | 52 | 64.5 | |
R4 | 63.5 | 79.4 | 54 | 66.6 | |
R5 | 48 | 79.4 | 40 | 66.6 | |
Motor capacity/rated current | Conveyor length | Conveyor length | |||
10000-70000 | 8KW/18A | 10000-80000 | 8KW/18A | ||
70001-110000 | 11KW/25A | 80001-110000 | 11KW/25A |