LE LE-T TAMURA 10A 15A 250V Temperature Metal Bimetal Thermal Cutoff Electric Fan Thermal Fuse
●It is a pellet type thermal links corresponding to RoHS.
●This thermal links adopted metal casing and sense temperature material of organic compound pellet.
●It is non-return type of thermal links. It means even if the ambient temperature falls after the thermal link operates but never re-connection.
●46 substances of very high concern (SVHC) specified by the REACH rule is not used. (46 substances are published on December 15, 2010)
LE-T TAMURA 10A 250V Metal Thermal Cutoff
Type: | LE***T Series, 10A 250V |
Temperature: | 73C To 216C |
Size: | 11xΦ4mm Body |
Model No. | TF | Fuse Temperature | TH | TM | Tr | Ur |
LE070T | 73℃ | 71±2℃ | 50℃ | 150℃ | 10A | 250V |
LE073T | 77℃ | 74±2℃ | 50℃ | 150℃ | 10A | 250V |
LE080T | 84℃ | 80±2℃ | 50℃ | 150℃ | 10A | 250V |
LE090T | 94℃ | 91±3℃ | 65℃ | 150℃ | 10A | 250V |
LE095T | 99℃ | 95±3℃ | 71℃ | 150℃ | 10A | 250V |
LE0105T | 113℃ | 109±2℃ | 85℃ | 150℃ | 10A | 250V |
LE0117T | 121℃ | 117±3℃ | 95℃ | 160℃ | 10A | 250V |
LE0124T | 128℃ | 124±3℃ | 102℃ | 160℃ | 10A | 250V |
LE0128T | 133℃ | 127+3/-2℃ | 105℃ | 160℃ | 10A | 250V |
LE0138T | 157℃ | 138±2℃ | 110℃ | 172℃ | 10A | 250V |
LE0152T | 172℃ | 152+3/-1℃ | 130℃ | 189℃ | 10A | 250V |
LE0169T | 184℃ | 167+1-3℃ | 145℃ | 210℃ | 10A | 250V |
LE0189T | 192℃ | 189±3℃ | 165℃ | 250℃ | 10A | 250V |
LE0213T | 216℃ | 213±2℃ | 190℃ | 380℃ | 10A | 250V |
LE TAMURA 15A 250V Metal Thermal Cutoff
Type: | LE*** Series, 15A 250V |
Temperature: | 73C To 216C |
Size: | 11xΦ4mm Body |
Model No. | Tf(℃) | Fuse Temperature (℃) | R(A) | Ur (V) | Th(℃) | Tm(℃) |
LE070 | 73 | 71±2 | 15.0160; | AC250 | 50 | 150 |
LE073 | 77 | 74±2 | 15.0160; | AC250 | 50 | 150 |
LE080 | 84 | 80±2 | 15.0160; | AC250 | 50 | 150 |
LE090 | 94 | 91+3/-2 | 15.0160; | AC250 | 65 | 150 |
LE095 | 99 | 95±2 | 15.0160; | AC250 | 71 | 150 |
LE108 | 113 | 109±2 | 15.0160; | AC250 | 85 | 150 |
LE117 | 121 | 117±3 | 15.0160; | AC250 | 95 | 160 |
LE124 | 128 | 124±3 | 15.0160; | AC250 | 102 | 160 |
LE128 | 133 | 129+3/-2 | 15.0160; | AC250 | 105 | 160 |
LE138 | 142 | 138±3 | 15.0160; | AC250 | 110 | 160 |
LE152 | 157 | 152±2 | 15.0160; | AC250 | 130 | 175 |
LE169 | 172 | 167±2 | 15.0160; | AC250 | 145 | 190 |
LE189 | 192 | 189±3 | 15.0160; | AC250 | 165 | 300 |
LE213 | 216 | 213±2 | 15.0160; | AC250 | 190 | 300 |
Terms Explaination
Rated function temperature(Tf) | The temperature at which an electrical or mechanical device operates. According to EC6091 saety stipulation, hermal fuse must operate at TF +0-10C. (DENAN Law regulates the tolerance range +7C) |
Measured function temperature: | The blowing temperature of the fuse measured in the condition that current is below 10MA and its temperature rises at the rate of 0.5-1t per minute in a silicon oil bath |
Holding temperature(Th) | The maximum temperature at which its conduction state would not change when the fuse is loaded with rated current for 168 hours. |
Maximum temperature(Tm) | The maximum temperature at which the fuse would not reconnect within 10 minutes. |
Rated current(r): | The maximum current the fuse can bear. |
Rated voltage(Ur): | The maxmum working voltage of the fuse |