Specifications
Brand Name :
TIAN RUI
Model Number :
CWFM0103FC1-xxxM113X
Certification :
ROHS
Place of Origin :
China
MOQ :
1000PCS
Price :
Negotiable
Payment Terms :
T/T, Paypal, Mastercard, Wetern Union, Alipay, etc
Supply Ability :
1000000PCS per Month
Delivery Time :
5-7 work days
Packaging Details :
PE bag, Bulk
Product Name :
Underfloor Heating 10K Temperature Sensor
Resistance at 25C :
10K ohm±1%
B25/50 :
3950K±1%
Probe Head :
6.5x20mm
Cable :
UL2464-22AWG PVC Cable
Wire Ends :
Tinned
Wire Length :
3 Meter or Customized
Application :
Control Temperature In Wet Room Or Bathroom
Color :
White
Operating Temp :
-30~+105C
Description

Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

Description Of Underfloor Heating Thermistor Temperature Sensor

The Probe and Sensor are used to control temperature where moisture would be a problem i.e. in wet room or bathroom. It can also control floor temperature where overheating would cause damage.

The temperature of an underfloor heating system is controlled via a thermostat that reads the temperature of the room through sensors. With underfloor heating, it’s common for there to be two types of sensor installed, the usual air sensor (in the thermostat itself) as well as an underfloor heating probe, or floor sensor.

Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

Features Of Underfloor Heating Thermistor Temperature Sensor

* Works with a wide range of different thermostats
* Please check the resistance values of your current sensor against the table below for compatibility
* Cable has high rigidity, allowing it to be easily passed through existing flexible conduit
* Suitable for use in wet areas. IP68 Rated (When installed according to manufacturers instructions)
* No polarity, simply connect the two wires either way round to the sensor outlet on the thermostat
* Rubber thermoplastic protective housing for NTC sensor

* The cable measures about 3 meters in length.
* Rubber thermoplastic protective housing for NTC sensor.
* This sensor has a resistance of 10K Ohms @ 25℃.
* Mainly used for underfloor heating thermostat to measure floor temperature, also suitable for monitoring piping water temperature, indoor temperature and outdoor temperature.
* Easy to connect with underfloor heating thermostat, the sensor probe can be stick to electrothermal film.

Dimension Of Underfloor Heating Thermistor Temperature Sensor

Unit:mm

Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

Dimension (unit:mm)
A B C D L
6.5 20 25±5 3±1 As required

Material Information Of Underfloor Heating Thermistor Temperature Sensor

NO Material Name Material and Specifications
2-1. Element R25=10KΩ±1% B25/50=3950K±1% DC
2-2. Coating NTC encapsulated using PVC over-mold material (White)
2-3 Cable features

UL2464-22AWG Tin plated copper cable with white PVC flat jacket wire 80℃ 300V

2-4. Wire ends Tinned

Performances Of Underfloor Heating Thermistor Temperature Sensor

NO Item Sign Test Conditions Min. Nor. Max. Unit
4-1. Resistance at 25℃ R25

Ta=25±0.05℃

PT≦0.1mw

9.9 10.0 10.1
4-2. B Value B25/50 3910.5 3950 3989.5 k
4-3. Dissipation factor σ In still air About 2 mW/℃
4-4. Time response τ In flowing water About 15 sec
4-5. Withstanding Voltage / 1500VAC 2Sec No breakdown Sec
4-6. Insulation Resistance 500VDC ≧100
4-7. Operating temp. range / / -30 / +105

Application Of Underfloor Heating Thermistor Temperature Sensor

1. Temperature measurement,
2. Sensing and control: White goods, Refrigerators, freezers, deep-freezers, coolers Ice cube makers
3. Floor heating system

How to Install an Underfloor Heating Thermistor Temperature Sensor


When installing a floor sensor, you should always follow the manufacturer’s instructions supplied however, there are some general rules that should be applied when installing any underfloor heating probe.
The probe should be placed equal distance between heating wires and should never cross a heating wire.
The probe can be installed either above or below your electric underfloor heating mat.
Areas in which the temperature may be affected such as near external doors or on heating pipes, should be avoided.


How to Test an Underfloor Heating Thermistor Temperature Sensor


During installation, the underfloor heating probe should be tested to ensure it is working correctly. This will be done by the installer. In order to do this, they will use a digital multimeter. A multimeter is an electronic measuring device that can usually measure voltage, resistance and current. In this case, your installer will be measuring resistance (ohms Ω).
To test if the underfloor heating sensor is working correctly, they will attach the multimeter probes to the floor sensor cable. At normal room temperature, the multimeter should read 10kΩ at 25°C. If this is the case your sensor cable is working correctly and the install can be completed.

Send your message to this supplier
Send Now

Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

Ask Latest Price
Watch Video
Brand Name :
TIAN RUI
Model Number :
CWFM0103FC1-xxxM113X
Certification :
ROHS
Place of Origin :
China
MOQ :
1000PCS
Price :
Negotiable
Contact Supplier
video
Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable
Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable
Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable
Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

Dongguan Tianrui Electronics Co., Ltd

Verified Supplier
5 Years
guangdong, dongguan
Since 2010
Business Type :
Manufacturer
Total Annual :
9000000-9500000
Employee Number :
150~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement