Item | Tube Fuse |
Standard | UL |
Blow Type | slow blow, time-lag |
Body Material | glass |
Fusing Material | tinned copper |
Cap Material | nickel plated brass |
Voltage Rating | 250V 125V |
Current Rating | 0.1A~20A |
Mounting Type | cartridge or axial leaded |
Breaking Capacity | 35A 100A 200A 10KA |
Size | 5.2x20 mm |
Certifications | CUL UL VDE CCC |
Applications | home appliance, power supply, telecommunication, consuming electronics |
TDS of TBC 5.2x20 glass tube fuse Slow Blow
Breaking Capacity UL certified
Amps(A) | Volts(V) | Interrupting Rating(A) |
0.2 - 0.25 | 125Vac | 10000 |
0.3 - 2 | 125Vac | 10000 |
2.5 - 10 | 125Vac | 10000 |
0.2 - 0.25 | 250Vac | 35 |
0.3 - 1 | 250Vac | 35 |
1.25 - 2 | 250Vac | 100 |
2.5 - 3.15 | 250Vac | 100 |
4 - 10 | 250Vac | 200 |
General electrical performace of the 5x20 slow blow glass fuse
Time vs Current Characteristics: IEC 60127-2/II | |||||
Rated current | 150% | 210% | 275% | 400% | 1000% |
250mA~6.3A | >1h | <30min | 250 ms~80 s | 50 ms~5 s | 5ms~150ms |
8A~10A | >30min | <30min | 750 ms~80 s | 95 ms~5 s | 5ms~150ms |
12.5A~16A | >30min | <30min | 750 ms~80 s | 150 ms~5 s | 5ms~150ms |
Amp Code | Rated Current | Rated Voltage | Voltage Drop Max(mV) | Max.Power Dissipation(W) | Typical Cold Resistance (mΩ) | Nominal Melting I2t(A2sec) | Breaking Capacity | Approvals | ||||
cURus | CQC | VDE | PSE | CCC | ||||||||
0250 | 250mA | 125 V AC 250 V AC | 1400 | 1.6 | 570 | 0.026 | 10KA/125V AC 100A/250V AC | ● | ○ | ○ | ○ | ○ |
0315 | 315mA | 1300 | 1.6 | 860 | 0.109 | ● | ○ | ● | ○ | ● | ||
0400 | 400mA | 1200 | 1.6 | 540 | 0.240 | ● | ○ | ○ | ○ | ● | ||
0500 | 500mA | 1000 | 1.6 | 220 | 0.168 | ● | ○ | ● | ○ | ● | ||
0630 | 630mA | 650 | 1.6 | 285 | 0.723 | ● | ○ | ● | ○ | ● | ||
0800 | 800mA | 240 | 1.6 | 120 | 0.757 | ● | ○ | ● | ○ | ● | ||
1100 | 1.00A | 200 | 1.6 | 101 | 1.64 | ● | ○ | ● | ● | ● | ||
1125 | 1.25A | 200 | 1.6 | 65.0 | 2.56 | ● | ○ | ● | ● | ● | ||
1150 | 1.50A | 190 | 1.6 | 51.47 | 3.76 | ● | ○ | ○ | ○ | ○ | ||
1160 | 1.60A | 190 | 1.6 | 50.35 | 4.00 | ● | ○ | ● | ● | ● | ||
1200 | 2.00A | 170 | 1.6 | 40.65 | 5.76 | ● | ○ | ● | ● | ● | ||
1250 | 2.50A | 170 | 1.6 | 30.00 | 9.61 | ● | ○ | ● | ● | ● | ||
1300 | 3.00A | 150 | 2.5 | 25.00 | 13.9 | ● | ○ | ○ | ○ | ○ | ||
1315 | 3.15A | 150 | 2.5 | 24.00 | 20.7 | ● | ○ | ● | ● | ● | ||
1400 | 4.00A | 130 | 2.5 | 17.60 | 22.1 | ● | ○ | ● | ● | ● | ||
1500 | 5.00A | 130 | 2.5 | 13.50 | 41.0 | ● | ○ | ● | ● | ● | ||
1630 | 6.30A | 130 | 2.5 | 10.60 | 70.6 | ● | ○ | ● | ● | ● | ||
1700 | 7.00A | 130 | 2.5 | 9.48 | 106 | ● | ○ | ○ | ○ | ○ | ||
1800 | 8.00A | 130 | 4 | 7.50 | 164 | ● | ● | ● | ● | ○ | ||
2100 | 10.00A | 130 | 4 | 6.30 | 272 | ● | ● | ● | ● | ○ | ||
2125 | 12.50A | 100 | 6 | 3.80 | 702 | ○ | ● | ○ | ○ | ○ | ||
2160 | 16.00A | 100 | 6 | 3.10 | 1332 | ○ | ● | ○ | ○ | ○ |
Note: (1) Permissible continuous operating current is 100% at ambient temperature of 23°C (73.4°F)
(2) The cURus certification by 125V and 250V; the VDE certification with 8A~10A by 125V and 250V; the others certification by 250V.
(3) The current values used for calculating I2T should be within the standard range of 8ms ~ 10ms.
Standard Package:
500pcs per bag, 5000pcs per box, 20000pcs per carton
Shipping Term:
EXW, DDU, DDP, C&F, FOB
Shipping Methods:
International Express, By Air, By Sea
Brand | Reomax | |||
Certificate | (CUL) (VDE) (CCC) (KC) | |||
Voltage Rating | 250V (125V) | |||
Current | 0.5A - 20A (Fast / Slow Blow) | |||
Operating Temperature | -40 - +125°C | |||
Tips: 1) These products are available in short lead time. 2) Please contact our us to get more details and Spe .We will provide the files immediately. |