Remote Control 220KW 3 Phase Biogas CHP 400V / 230V Clean Power CE Approved
HIGH ALTITUDE OPERATION
At high altitude, the standard gas mixer will be excessively rich. Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller diameter main fuel jet in the mixer and readjusting the pilot screw. If you always operate the engine at altitudes higher than 5000 feet (1500 meters) above sea level, have an authorized CHP dealer perform this mixer modification.
Even with suitable mixer jetting, engine horsepower will decrease approximately 3.5% for each 1000 foot (300 meter) increase in altitude. The effect of altitude on horsepower will be greater than this if no carburetor modification is made.
CHP Main Specifications
Model | SP220B | |
fuel | — | Biogas |
marks | — | Synchro CHP |
electrical output(KWe) | kVA/kWe | Continuous Power |
313/220 | ||
thermal output(KWe) | kWt | 315 |
electrical efficiency | % | 34% |
thermal efficiency | % | 48.7% |
overall efficiency | % | 82.7% |
frequency | Hz | 50 |
voltage | V | 400/230 |
gas inlet pressure | kPa | 3-5 |
dimension (soundproof type) | mm*mm*mm | 3500*1800*2000 |
net weight | kg | 4000 |
Biogas consumption | m3/kW.h | 0.41 |
Biogas consumption for one hours | m3/h | 102.5 |
db(A)@7m | — | 59 |
Certificate | — | CE |
water-water heat exchanger | — | SWEP |
water-exhaust heat exchanger | — | made of stainless steel |
ignition system | — | Altronic |
speed governor | — | Woodward |
gas filter | — | Madas |
zero regulator | — | Kromschroeder |
MCB | — | ABB |
GCB | — | ABB |
Controller | ComAp | |
Engine model | — | MAN MT13 |
Engine type | — | 6 cylinders,4stroke,water-coolled |
RPM | — | 1500 |
Compression Ratio | — | 11.5 |
Displacement | — | 12.419L |
Oil capacity | — | 40L |
Charging voltage | — | 24V(DC) |
Charging current | — | 5A(DC) |
Starting system | — | Electic-start |
Alternator model | — | Meccalte |
phase | — | 3 phase 4 wires |
insulation system | — | class H |
protection | — | IP23 |
Cooling Type | — | air cooled |
Characters
Environmentally friendly design.
Long time R&D and testing ensure high reliability.
Comprehensive heat insulation to minimize heat loss.
CHP inner pipelines are made of full stainless steel material.
Maximum lower the noise level.
Maintenance friendly thanks to easy access.
Biogas Requirements
Composition | Content |
CH4 | ≥55% |
fluctuations value of biogas in pipeline | <0.2Kpa |
hydrogen | <10% |
sulfide, including hydrogen sulphide | <200mg/m3 |
chlorine fluorine compounds,mainly chlorofluoromethane | <15mg/m3 |
silicium | <0.7mg/m3 |
ammonia | <15mg/m3 |
liquid oil and hydrocarbons | <50mg/m3 |
particles | <5μm Impurity content<30mg/m3 |
For more information about each CHP, please consult with your sales representative.Thanks.
More Information About Our Factory
Our Packing
Our Hannover Exhibition
Our Showroom In Germany
Our Customers' Visiting