Biogas CHP 30KW 40KVA CE Certified For Heating Hot Water Farm Power Supply
Biogas Requirements
-CHP4 ≥55%
-fluctuations value of biogas in pipeline <0.2Kpa
-hydrogen <10%
-sulfide, including hydrogen sulphide<200mg/m3
-chlorine fluorine compounds,mainly chlorofluoromethane<15mg/m3
-silicium<0.7mg/m3
-ammonia<15mg/m3
-liquid oil and hydrocarbons<50mg/m3
-particles<5μm Impurity content<30mg/m3
Different Configurations For Different Application
-Standalone off-grid operation or Synchronize to grid
-With or Without ATS
-With or Without soundproof canopy
-With or Without catalyst converter to reach emissions limit
-Single unit or several units in parallel
-Remote control
Model | SP32B | |
fuel | — | Biogas |
marks | — | Synchro CHP |
electrical output(KWe) | kVA/kWe | Continuous Power |
38/30 | ||
thermal output(KWt) | kWt | 53 |
electrical efficiency | % | 29.1% |
thermal efficiency | % | 51.4% |
overall efficiency | % | 80.5% |
frequency | Hz | 50 |
voltage | V | 400/230 |
gas inlet pressure | kPa | 3-5 |
dimension (soundproof type) | mm*mm*mm | 2100*1200*1500 |
net weight | kgs | 1100 |
biogas consumption | m3/kW.h | 0.48 |
standard type-db(A)@7m | — | 58 |
Certificate | — | CE |
water-water heat exchanger | — | SWEP |
water-exhaust heat exchanger | — | designed by our own factory/made of full stainless steel |
ignition system | — | Impco |
speed governor | — | Woodward |
mixer | — | Venturi type |
gas filter | — | Madas |
zero regulator | — | Maxitrol |
solenoid valve | — | Kromschroeder |
gas pressure gauge | — | Dungs |
Lambda auto control | — | Available on request with extral cost |
catalyst converter | — | Available on request with extral cost |
MCB | — | ABB |
GCB | — | ABB |
Controller | ComAp | |
Engine model | — | SP-4BTA |
Engine type | — | 4 cylinders,4stroke,water-coolled |
RPM | — | 1500 |
Compression Ratio | — | 10.5 |
Displacement | — | 3.9L |
Oil capacity | — | 9.5L |
Charging voltage | — | 24V(DC) |
Charging current | — | 5A(DC) |
Starting system | — | Electic-start |
Alternator model | — | Meccalte |
phase | — | 3 phase 4 wires |
insulation system | — | class H |
protection | — | IP23 |
Cooling Type | — | air cooled |