Specifications
Brand Name :
Guangzhou Xinlin Firefighting Equipment Co., Ltd.
Model Number :
DMP80/20-XL-304
Certification :
ISO9001,CE,QMS,CCCF,CNAS
Place of Origin :
China
MOQ :
5 set system
Price :
negotiation
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
150000 sets per week
Delivery Time :
10-15 working days after payment or receipt of L/C
Packaging Details :
Plywood outer box with bubble bag or paper
Starting Mode :
Automatic, Electrical Manual, Mechanical Emergency
Feature :
Clean Gas and Environmental Friendly
Body Material :
Steel Cylinder
Pressure :
20MPa
Type :
Automatic Fire Extinguisher
Object :
Class a, B, C, E Fires
High Light :
DMP80/20-XL-304 fire suppression equipment
Description

Piston Flow Fire System clean gas fire extinguisher Device IG541

Product description

The IG541 gas fire extinguishing system is an efficient, environmentally friendly and relatively safe fire extinguishing system for the human body. It is widely used in the protection areas of various important facilities and high-value assets. This system occupies an important position in the field of modern fire safety with its unique fire extinguishing mechanism and excellent environmental protection characteristics.


Fire extinguishing agent composition and characteristics
IG541 fire extinguishing agent is a mixture of three natural gases present in the atmosphere - nitrogen (N2), argon (Ar) and carbon dioxide (CO2) in precise proportions of 52%, 40% and 8%. This mixed gas has the following salient features:
1. Colorless, odorless, non-toxic and non-conductive**, ensuring that the impact on personal safety and sensitive equipment is minimized during the fire extinguishing process.
2. It has excellent environmental protection performance because its ozone depletion potential (ODP) is zero and greenhouse effect potential (GWP) is also zero, and it is harmless to the atmospheric environment after release.
3. Fire extinguishing principle: The IG541 fire extinguishing system mainly relies on the suffocation fire extinguishing principle. By reducing the oxygen concentration in the protective zone to about 12.5%, the fire source cannot obtain enough oxygen to support combustion, thereby extinguishing the fire.


System composition
The IG541 gas fire extinguishing system mainly consists of two parts: alarm control subsystem and pipe network subsystem.
The alarm control subsystem includes gas fire extinguishing controller, emergency start and stop button, manual automatic transfer switch, fire sound and light alarm, gas release alarm and various fire detectors (such as smoke and temperature detectors, etc.). To monitor fire conditions and trigger fire extinguishing procedures.
The pipe network subsystem** consists of fire extinguishing agent containers, mechanical and automatic starting devices, high-pressure hoses, manifolds, safety valves, check valves, selector valves, pressure switches, pipes and nozzles, etc. to ensure that the fire extinguishing agent can Quickly and effectively transport it to the designated protection area when a fire occurs.
Working principle and control method
Once the fire is sensed by the detector, the system starts the response program according to the preset control method:
Automatic control: After the system receives the fire alarm signal, after a certain delay (usually 30 seconds to provide time for personnel to evacuate), the system automatically activates the corresponding fire extinguishing device and releases IG541 fire extinguishing agent to the protective area.
Manual control: In an emergency, the system can be manually started to extinguish the fire through the gas fire extinguishing controller or the emergency start button at the entrance to the protective zone.
Mechanical emergency operation**: If the electronic control system fails, emergency fire extinguishing can also be started mechanically.

scenes to be used
Due to the safety and environmental friendliness of the IG541 gas fire extinguishing system, it is suitable for a variety of scenarios:
1. Data centers, communication equipment rooms, libraries, archives and other places that have strict protection requirements for precision electronic equipment and important paper documents.
2. Storage areas for precious artworks and historical relics such as museums and art exhibition halls.
3. Important fire prevention areas in distribution rooms, generator rooms and other electrical facilities.
4. Medical and scientific research laboratories and other places that have high requirements for clean environment and personnel safety.
5. Other special areas where it is not suitable to use water to extinguish fires or where the spread of fire must be quickly suppressed and damage to the surrounding environment caused by the fire extinguishing process must be minimized.


In short, the IG541 gas fire extinguishing system has become an ideal fire extinguishing solution for many key facilities and important places with its efficient fire extinguishing capabilities, good environmental protection characteristics and low risk to personnel.

Technical parameter

Model
DMP80/20-XL-304
Agent
N 2,Ar,C0 2 (proportion52%,40%,8%)
Executive standards
GB25972-2010
Working pressure (20ºC)
15MPa
Working pressure temperature
0~50°C
Filling density (20°C)
211.15kg/M 3
Maximum working pressure(50°C)
17.2MPa
Fire extinguishing methods
Total flooding fire extinguishing
Starting Method
Automatic, pneumatic, and mechanical emergency operations
Spraying time
≤60S
Drive bottle group pressure
6Mpa
Application place
Computer room, communication room, control room, valuable equipment room.cultural relics collection library and archive room, data storage room, generator room, transformer room, substation circuit breaker, circulating equipment hydraulic equipment, drying equipment, dust removal equipment painting production line.etc

Company profile

Guangzhou Xinlin Firefighting Equipment Co., Ltd. is located in Guangzhou, a vital city connecting China to the world, characterized by its convenient transportation and picturesque environment. We are a manufacturing company with a professional and seasoned team of employees, consisting of solution design experts, technical installation specialists, quality inspection professionals, and after-sales service teams, dedicated to the research and development of HFC-227ea (FM200), IG541, IG100, and Novec 1230 products.

Currently, we offer a range of commonly used fire suppression systems, including FM200 fire suppression systems, cabinet-style FM200 fire suppression systems, fully automatic fire extinguisher (hanging),portable fire extinguisher,IG541 fire suppression systems, IG100 fire suppression systems, fire detection tube fire suppression systems, as well as automatic fire extinguishing pipelines.

With high quality products, perfect service and good reputation, the company has won wide praise from customers at home and abroad.

Why choose us

-----------------------------------------------------------------------------------

• Efficient management system

• More than 10 years of experience in gas fire fighting industry

• Advanced equipment and professional engineers

• We provide 8×6 hr technical support and after-sales service

Frequently Asked Questions

-----------------------------------------------------------------------------------

Q1Are you a manufacturer or a trading company?

A1: We are the manufacturer.

Q2: Do you have OEM orders?

A2: Yes, according to the customer's requirements.

Q3: Where is your factory located? How do I get there?

A3: Our factory is located in Dongzhou Industrial Park, Xintang Town, Zengcheng District, Guangzhou City, Guangdong Province, China.

You are very welcome to visit our factory.

Send your message to this supplier
Send Now

Piston Flow Fire System Clean Gas Fire Extinguisher Device IG541

Ask Latest Price
Watch Video
Brand Name :
Guangzhou Xinlin Firefighting Equipment Co., Ltd.
Model Number :
DMP80/20-XL-304
Certification :
ISO9001,CE,QMS,CCCF,CNAS
Place of Origin :
China
MOQ :
5 set system
Price :
negotiation
Contact Supplier
video
Piston Flow Fire System Clean Gas Fire Extinguisher Device IG541

Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.

Verified Supplier
2 Years
guangdong, guangzhou
Since 2017
Business Type :
Manufacturer
Total Annual :
500000-1000000
Employee Number :
20~99
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement