Smart Flexible Thin Film Pressure Sensor ZD10-100 for Health
Description
ZD10-100 flexible thin film pressure sensor is a new type of sensor with independent intellectual property rights of flexible pressure sensor technology. It is printed on flexible thin material with strong adhesion, bending resistance and high sensitivity of flexible Nano functional materials, so as to achieve high sensitivity of pressure detection.
The flexible film pressure sensor is a resistive sensor. The output resistance decreases as the pressure applied to the surface of the sensor increases. The pressure can be measured through a specific pressure-resistance relationship.
ZD10-100 is mainly used for small pressure detection in a certain area. Its response point is as low as below 50g, which can effectively detect the pressure trigger and pressure change on the surface of the ZD10-100 sensor. Can be widely used in smart home, consumer electronics, automotive electronics and other fields
Features
Ø Ultra-thin,thickness less than 0.3mm
Ø Flexible waterproof package
Ø bending resistance
Ø Quick response
Ø Long life,passed the pressing test of more than 1 million times
Ø The output signal is easy to detect
Ø Customizable product length, size, pin package, etc.
Ø The sensor range parameters can be customized
Performance Index
Model | ZD10-100 |
Range | 0~500g |
Thickness | ≤0.3mm |
Dimension | See specification and size description |
Response point1 | ≤50g |
Repeatability | ±5%(50%loaded) |
Consistency2 | ±15%(Batch of the same model) |
Hysteresis | +10% (RF+ - RF-)/RF+ |
Durability | >One million times |
Initial Resistance | >10MΩ(Non-Loaded) |
Response Time | <1ms |
Resume Time | <15ms |
Test Voltage | Typical Value DC 3.3V |
Operating Temperature | -20℃ ~ 60℃ |
EMI | No produce |
ESD | Insensitivity |
Data reference sheet
Model | Pressure/gf | 50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 |
ZD10-100 | Resistance/KΩ | 10.29 | 5.34 | 3.98 | 3.32 | 2.98 | 2.82 | 2.66 | 2.55 | 2.47 | 2.43 |
Note: The curve in the icon is drawn from data measured under specific conditions. The relationship of the curve is for reference only. The actual data should be tested after installation according to the specific application.
Reference Circuit
Instructions
- ZD10-100 flexible pressure sensor is a non-polar component, there is no directionality in the circuit;
- When using, please place the pressure sensitive zone of the sensor on a firm, flat surface. Using the sensor on a curved or irregular surface will make the sensor initially conductive, that is, in a "response" state when there is no pressure; in this state, the sensor output resistance can still respond to pressure changes, and the corresponding relationship is no longer applicable to the reference data sheet;
- If the supporting surface and the force application surface are both rigid and hard surfaces, and the contact surface is larger than the sensor size (sensor sensitive area size 52mm*10mm), due to the sensor's own structure, the pressure response may be small and unstable. A round soft rubber pad needs to be affixed to the center of the sensitive area, the diameter is slightly smaller than the sensitive area, and the area should be greater than 60% of the area of the sensitive area;
- You can use double-sided tape to fix the sensor on the supporting surface. Pay attention that the supporting surface is tidy and clean before pasting. It is recommended to use 3M brand double-sided tape; provide customized services;
- After the sensor is stressed and maintains the pressure, the output resistance value will drift slightly over time, usually within 5%. This error can be reduced by the method of timing calibration. In the calibration operation, the waiting time after applying pressure is consistent with the waiting time in actual applications. Since the force state of the sensor is different in different application scenarios, it is recommended that the user arrange the sensor according to the actual application scenario and test the drift parameters by themselves.
Announcements
- When using the sensor, try to make the load received evenly and avoid direct contact with the sensor by sharp objects;
- Over-range use will reduce the performance of the sensor or even destroy the sensor;
- The sensor terminal is made of copper and tin-plated material, and the lead can be welded according to the needs. It should be noted that the soldering temperature should not be too high, it is recommended that it should not exceed 300°C, and the contact time should not exceed 1 second, so as to prevent the high temperature from melting and deforming the film substrate.