600kW Auxiliary Power of Oil Field Generator
Descriptions
1. Engine monitor: coolant, lubrication, exhaust, battery
2. Modbus communication protocol based on RS232 and RS485 interfaces
3. Supply gas circuit monitor: pressure, temperature and CH4 content
4. SMS message
5. Auto paralleling and load share
6. Internet connection and USB 2.0 interface
7. Voltage and PF control
Model | Efficiency | Fuel Type | Engine Model | Alternator | Genset Controller | ||||
Elec. | Thermal | Total | Manufacturer | Model | Manufacturer | Model | |||
JIG600NS-T | 37.3% | 44.8% | 82.1% | Natural Gas | U26556N | Mecc Alte | ECO38 2L4 A | DEIF | AGC200 |
Genset | Genset Model | JIG600NS-T | |
Prime Rating | kW | 600 | |
KVA | 750 | ||
Standby Power | kW | 660 | |
KVA | 825 | ||
Rated Voltage | V | 230/400 | |
Rated Current | A | 1082.6 | |
Power Factor | - | 0.8 | |
Rated Frequency | Hz | 50 | |
Rated Speed | rpm | 1500 |
Spec | Dimensions (Silent Canopy) (L × W × H) | mm | 6875×3200×2350 | ![]() | |||||
Net weight (Silent Canopy) | kg | 13500 |