Container Type 1000KW-400V Generator Load Bank for 800KW Generator
Typical Applications:
1. In the acceptance inspection of load bank, the relevant department have to check whether the new devices fulfill the actual requirement.
2. After the installation of noise reduction devices, the loading capability must be test again.
3. For the routine test & maintenance, it is essential to test the output power and loading capability.
Main features of the generator load bank:
1. Power: 1KW-10MW
2. PF: 0.8-1.0
3. Fans cooling or water cooled
4. Inductive / Resistive or non-inductive
5. Manual/PLC remote control
6. Load steps(by switches) / infinite adjust
7. Current: 0.1A-10000A
8. Working voltage: DC/AC 1V-1000V
9. Value: 0.01Ω-100KΩ
10. Working Environment:
Altitute: ≤2500m
Temperature: -10°C~50°C
Humidity: ≤95%RH
Working Mode: Continuous work
11. IP class: IP20-IP67
12. Nice appearance, reasonable structure;
Good sealing: be able to work under rain, snow, dust, or any other harsh environment.
Introduction of the generator load bank:
Power generator intelligent testing system can accurately test the output power and loading capacity of various generator units,test all the electric parameters including dynamic parameters of generator units,and mainly consists of two parts:testing control and load cabinet,which is used in coordination with host computer thus materializing intelligentization and automatization to complete the testing of all electric parameters of generator unit,meanwhile,charts,curves and testing report are produced,and no manual operation is required(intelligently controlled,manual/automatic may be selected),to provide scientific testing means for large power generator units.
Technical Parameters for reference:
System components | Load bank, resistive load,data collection, automatic control and manual control, electrical control, cooling devices and auxiliary control,Industrial machines, printer. |
Total discharge power | 1000KW |
Resistive load stalls | step: 5KW |
Test voltage | Three-phase AC400V |
Test Frequency | 50Hz |
Resistance tube | Insulation resistance of each resistor above DC500V 100MΩ , Pressure AC2000V 1 minute, Resistance to high temperature. |
Load connection | Star (three-phase four -wire) |
Loading precision | ±3% |
Work way | Continuous work |
Working power | 480VAC/50Hz/Three-phase four-wire system; (reservation terminals) |
Operator terminal | IPC / software, full realization of automated control |
Control mode | Manual control / computer software auto control |
Measured Control Function | Load subtraction control, extended load automatic identification synchronization control |
IPC detection function | I, V, HZ, KW, COSΦ etc.Real-time display, electrical performance testing, curves and report output, system electrical parameters monitoring, automatic data acquisition; |
Parameter record | Form through EXCEL, curves pictures saved by WORD document |
Parameter display | three-phase voltage, three- phase current, apparent power, active power, reactive power, power factor, frequency, etc.; |
Load protection | Overvoltage, overcurrent, high temperature, air flow and fan failure protection; |
Fault alarm | Fan failure, load high temperature alarm |
Dimension | 3000*2000*2000 |
Weight | 2000kg |
Applicable Scope | For marine diesel generator sets, land diesel generators, power inverters, UPS systems |