Generator Test Load Bank With Copper Inductor for Generator Load Test
Control Function:
1. Load testing: load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.
2. Load/unload with one key: Whether manual control, remote control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.
3. Control Pattern: user can choose local control and intelligent control.
4. Local Control: There is local control panel with several power steps; user can load/unload by button. Each gear switch with indicator light.
5. Intelligent Control: Through data processing software in PC, user can make automatic load, to display, record and manage the testing data, to form curves, tables, also to print them.
6. Local meter display data: local meter can display 3 phases voltage, current, active power, frequency and so on.
Application:
Used for the testing of output power and loading capacity. The equipment uses graded loads to make any combination based on testing needs.The system uses air cooling with overvoltage,low voltage,overheat and short circuit warning functions to ensure the safety and reliability of equipment.
Why choosing us?
* The professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 11 years.
* The most patent technology and scientific research awards gainer in China.
* Advanced detection method and strict inspection procedure build the qualified quality.
* Customized production meet the individual requirement.
* Prompt delivery & excellent after sales service.
* Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
* Certified with China Classification Society (CCS) and ISO9001 Quality Certificate.
Specification | |
Rating voltage/frequency | 500VAC |
Max Load Power | Power:42.5kW |
Load Resolution | Step:1A |
Power Factor | 1 |
Load Tolerance | ±5% |
Fan Control Power | 110V/220V,50Hz/60Hz |
Wire Connection | Load bank input——Copper bar |
Control power input——Connector-bar | |
Max Protection Grade | IP32 |
Way of Working | Continuous Working |
Cooling | Forced air cooling, horizontal inlet air and upwards exhaust cooling |
Transportation | Hoisting |
Color | RAL7032 |
Dimensions | 750*800*1300 |
Weight | 130KG |
Accessories | Switch: ABB, Siemens and Schneider, PLC: Panasonic and Siemens; |
Operating Environment Parameter | |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |