Specifications
Place of Origin :
China
Brand Name :
GSKA
Model Number :
JP-P2200E
MOQ :
20-30 pieces
Price :
Negotiable
Packaging Details :
Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time :
3-5 days on receipt of official sales contract
Payment Terms :
L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability :
500 pieces per Month
Port: :
HongKong or ShenZhen,ShangHai,Dalian as required
CertifiCAT-partsion :
CE,GS,EPA,CARB,CSA
Description


1, Engine Make & Model:Perkins 4016TAG2A

2,Generating Set Model: P2200E

3,Alternator Model:LL9124H

4, Circuit Breaker Type: 3 Pole ACB

5, Frequency: 50 Hz / 60 Hz

6,Cycle: 4 Stroke

7, Engine Speed: 1500rpm

8, Cooling Method: Turbo, Water/Air cooling

9, Governing Type: Electronic

10, Output Type: AC Three Phase

10, No.of Cylinders/Alignment: 16 / Vee

11,Base Frame Type: Heavy Duty FabriCAT-parts-partsed Steel

P2200E Perkins Diesel Generator , 3 Pole ACB

Output Ratings

Generating Set Model

*P2200E Prime* Standby*

380-415V, 50 Hz

2000.0 kVA 2200.0 kVA

1600.0 kW 1760.0 kW

220/127V, 60 Hz

- -

- -

  • Refer to ratings definitions on page 4.

Ratings at 0.8 power factor.

Technical Data

Engine Make & Model:

Perkins 4016TAG2A

Alternator Model:

LL9124H

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole ACB

Frequency:

50 Hz 60 Hz

Engine Speed: RPM

1500 -

Fuel Tank Capacity: litres (US gal)

-

Fuel Consumption: P2000 l/hr (US gal/hr)

423.5 (111.9) -

Fuel Consumption: P2200E l/hr (US gal/hr)

474.1 (125.2) -

P2000 / P2200E

Engine Technical Data

Physical Data Air System 50 Hz 60 Hz

Manufacturer: Perkins

Model: 4016TAG2A

No. of Cylinders/Alignment: 16 / Vee

Cycle: 4 Stroke

Induction: Turbocharged Air To Air Charge Cooled

Cooling Method: Water Governing

Type: Electronic Governing

Class: ISO 8528 G2

Compression Ratio: 13.6:1

Displacement: l (cu.in) 61.1 (3730.0) Bore/Stroke: mm (in) 160.0 (6.3)/190.0 (7.5) Moment of Inertia: kg m² (lb. in²) 20.72 (70803)

Engine Electrical System:

-Voltage/Ground: 24/Negative

-Battery Charger Amps: 40

Weight: kg (lb) - Dry: 5570 (12280)

- Wet: 5847 (12890)

Air Filter Type: Replaceable Element Combustion

Air Flow:

m³/min (cfm)

-Standby: 145.0 (5121) -

-Prime: 137.0 (4838)

- Max. Combustion Air Intake

Restriction: kPa (in H2O) 3.7 (14.9)

- Radiator Cooling Air Flow:

m³/min (cfm) 2058.0 (72678)

- External Restriction to

Cooling Air Flow: Pa (in H2O) 250 (1.0) -

Cooling System 50 Hz 60 Hz

Cooling System Capacity:l (US gal) 355.0 (93.8)

- Water Pump Type: Centrifugal Heat Rejected to Water &

Lube Oil: kW (Btu/min)

-Standby: 721.0 (41003) -

-Prime: 660.0 (37534)

- Heat Radiation to Room:

kW (Btu/min) -Standby: 231.0 (13137) -

-Prime: 200.0 (11374)

- Radiator Fan Load: kW (hp) 63.5 (85.2) -

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

Performance 50 Hz 60 Hz

Engine Speed: RPM 1500 - Gross Engine Power: kW (hp)

-Standby: 1937.0 (2597.6) -

-Prime: 1766.0 (2368.2) - BMEP: kPa (psi)

-Standby: 2535.2 (367.7) -

-Prime: 2311.1 (335.2) - Regenerative Power: kW 160.0 -

LubriCAT-parts-partsion System

Oil Filter Type: Spin-On, Full Flow

Total Oil Capacity l (US gal): 238.0 (62.9)

Oil Pan l (US gal): 214.0 (56.5)

Oil Type: API CG4 15W-40

Cooling Method: Water

Fuel System

Fuel Filter Type: Replaceable Element Recommended

Fuel: Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

110% 100% 75% 50% Load Load Load Load

P2000

50 Hz 474.1 (125.2) 423.5 (111.9) 312.9 (82.7) 212.9 (56.2)

60 Hz - - - -

P2200E

50 Hz 474.1 (125.2) 344.9 (91.1) 232.1 (61.3)

60 Hz - - -

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

Exhaust 50 Hz 60 Hz

Silencer Type: Level 1

Silencer Model & Qty: SD350 (1)

Pressure Drop Across

Silencer System: kPa (in Hg) 0.50 (0.148)

- Silencer Noise Reduction

Level: dB 17

- Max. Allowable Back

Pressure: kPa (in. Hg) 6.6 (1.9)

- Exhaust Gas Flow:

m³/min (cfm)

-Standby: 387.0 (13667) -

-Prime: 387.0 (13667) - Exhaust Gas Temperature: °C (°F)

m³/min (cfm)

-Standby: 493 (919) -

-Prime: 493 (919)

P2000 / P2200E

Alternator Performance Data

Data Item

50 Hz 60 Hz

415/240V

400/230V

380/220V

Motor Starting Capability* kVA

6986

6509

5897

Short Circuit Capacity** %

300

300

300

Reactances: Per Unit

Xd X'd X''d

3.230

0.240

0.126

3.480

0.260

0.136

3.850

0.290

0.151

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

Alternator Technical Data

Physical Data Operating Data

Manufacturer: FG WILSON

Overspeed: RPM 2250

Model: LL9124H

Voltage Regulation (steady state) (%): + /- 0.5

No. of Bearings: 1

Wave Form NEMA = TIF: 50

Insulation Class: H

Wave Form IEC = THF: 2.0%

Winding Pitch Code: 2/3 - 6S

Total Harmonic Content LL/LN: 2.5%

Wires: 6

Supression is in line with European Standard

Radio Interference: EN61000-6

Ingress Protection Rating: IP23

Radiant Heat: kW (Btu/min)

-50 Hz: 81.0 (4606)

-60 Hz: -

Excitation System: AREP

AVR Model: R449

P2000 / P2200E

Technical Data

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz- RPM

Voltage Prime Model Standby Model Voltage Prime Model Standby Model

P2000 P2200E - -

kVA kW

kVA kW

kVA kW

kVA kW

415/240V

2000.0 1600.0

2200.0 1760.0

400/230V

2000.0 1600.0

2200.0 1760.0

380/220V

2000.0 1600.0

2200.0 1760.0

Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

60Hz Perkins Diesel Generator , 3 Pole ACB , P2200E , Three Phase

Weights and Dimensions

Weights and Dimensions

60Hz Perkins Diesel Generator , 3 Pole ACB , P2200E , Three Phase

General Data

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

Warranty

All equipment carries full manufacturer's warranty.

Send your message to this supplier
Send Now

60Hz Perkins Diesel Generator , 3 Pole ACB , P2200E , Three Phase

Ask Latest Price
Place of Origin :
China
Brand Name :
GSKA
Model Number :
JP-P2200E
MOQ :
20-30 pieces
Price :
Negotiable
Packaging Details :
Standard plywood and wood package.the actual package size against goods size and handle requires.
Contact Supplier
60Hz Perkins Diesel Generator , 3 Pole ACB , P2200E , Three Phase
60Hz Perkins Diesel Generator , 3 Pole ACB , P2200E , Three Phase

Guangdong ALI Testing Equipment Co,.Ltd

Active Member
13 Years
guangdong, dongguan
Since 1985
Business Type :
Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company
Total Annual :
4Million-5Million
Employee Number :
50~100
Certification Level :
Active Member
Contact Supplier
Submit Requirement