1, Manufacturer / Model: CCEC Cummins KTA19-G4, 4-cycle
2, Air Intake System: Turbo, Water/Air cooling
3, Fuel System: PT type fuel pump, EFC
4, Cylinder Arrangement: 6 in line
5, Displacement: 19L
6, Rated RPM: 1500rpm
7, Governor Type: Electronic
4-Cycle Portable Diesel Generator , Cummins KTA19-G4
Standby Power(50Hz) 440KW / 550KVA
Prime Power(50Hz) 400KW / 500KVA
Dimension & Weight
Standard Configuration (Open Type)
Overall Size: 3400(mm)×1360(mm)×1980(mm)
Weight: 4040kg
General Features:
Engine (CCEC Cummins KTA19-G4)
Radiator 40OC max, fans are driven by
belt, with safety guard
24V charge alternator
Alternator: single bearing alternator IP23,
insulation class H/H
Absorber
Dry type air filter, double fuel filter, oil filter,
coolant filter
Main line circuit breaker
Standard control panel
Two12V batteries, rack and cable
Ripple flex exhaust pipe, exhaust siphon,
flange, muffler
User manual
Engine Data
Manufacturer / Model: CCEC Cummins KTA19-G4, 4-cycle
Air Intake System: Turbo, Water/Air cooling
Fuel System: PT type fuel pump, EFC
Cylinder Arrangement: 6 in line
Displacement: 19L
Bore and Stroke: 159*159(mm)
Compression Ratio: 13.9:1
Rated RPM: 1500rpm
Max. Standby Power at Rated RPM: 504KW/675HP
Governor Type: Electronic
Exhaust System Exhaust Gas Flow: 1604L/s Exhaust Temperature: 557℃ Max Back Pressure: 10kPa Air Intake System Max Intake Restriction: 6.23kPa Consumption: 579L/s Air Flow: 9800L/s Fuel System 100%( Prime Power) Load: 203 g/Kw.h 75%(Prime Power) Load: 207 g/Kw.h 50%(Prime Power) Load:: 216 g/Kw.h 100%( Prime Power) Load: 101.9L/h Oil System Total Oil Capacity: 50L Oil Consumption: ≤4g/kwh Engine Oil Tank Capacity: 38L Oil Pressure at Rated RPM: 345-483kPa Cooling System Total Coolant Capacity: 106L Thermostat: 82-93℃ Max Water Temperature: 104℃ |
|
Alternator SpecifiCAT-parts-partsion
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data
Number of Phase: 3 Connecting Type: 3 Phase and 4 Wires, “Y” type connecting Number of Bearing: 1 Power Factor: 0.8 Protection Grade: IP23 Altitude: ≤1000m Exciter Type: Brushless, self-exciting Insulation Class, Temperature Rise: H/H Telephone Influence Factor (TIF): <50 THF: <2% Voltage Regulation, Steady State: ≤±1% Alternator Capacity: 500KVA Alternator Efficiencies: 93.8% Air Cooling Flow: 1.035m3/s |
|
Generating set data:
Voltage Regulation: ≥±5% Voltage Regulation, Stead State: ≤±1% Sudden Voltage Warp (100% Sudden Reduce): ≤+25% Sudden Voltage Warp (Sudden Increase): ≤-20% Voltage Stable Time (100% Sudden Reduce): ≤6S Voltage Stable Time (Sudden Increase) ≤6S Frequency Regulation, Stead State: ≤5% Frequency Waving: ≤0.5% Sudden Frequency Warp (100% Sudden Reduce): ≤+12% Sudden Frequency Warp (Sudden Increase): ≤-10% Frequency Recovery Time (100% Sudden Reduce): ≤5S Frequency Recovery Time (Sudden Increase): ≤5S |
|
|
|
Options
Competitive Advantage:
High Performance of loading Easy start
Nice protection User-friendly operation
Low running cost Environmental Long service life