1, Model:CCEC Cummins KTA19-G3
2, Air Intake System:Turbo, Water/Air cooling
3, Fuel System:PT type fuel pump, EF
4, Cylinder Arrangement:6 in line
6, Bore and Stroke:159*159(mm)
7, Rated RPM:1500rpm
8, Max. Standby Power at Rated RPM:1227KW/1669HP
9, Governor Type:Electronic
400KW / 500KVA Cummins Diesel Generator Sets , KTA19-G3
Standby Power(50Hz) | 400KW / 500KVA |
Prime Power(50Hz) | 360KW / 450KVA |
Dimension & Weight
Standard Configuration (Open Type) |
Overall Size: 3400(mm)×1380(mm)×1980(mm) |
Weight: 4000kg |
General Features: |
Engine (CCEC Cummins KTA19-G3) |
Radiator 40OC max, fans are driven by belt, with safety guard |
24V charge alternator |
Alternator: single bearing alternator IP23, insulation class H/H |
Absorber |
Dry type air filter, double fuel filter, oil filter, coolant filter |
Main line circuit breaker |
Standard control panel |
Two12V batteries, rack and cable |
Ripple flex exhaust pipe, exhaust siphon, flange, muffler |
User manual |
Engine Data
Manufacturer / Model | CCEC Cummins KTA19-G3, 4-cycle |
Air Intake System | Turbo, Water/Air cooling |
Fuel System | PT type fuel pump, EF |
Cylinder Arrangement | 6 in line |
Displacement | 18.9 |
Bore and Stroke | 159*159(mm) |
Compression Rate | 14.5 |
Rated RPM | 1500rp |
Max. Standby Power at Rated RPM | 448KW/609H |
Governor Type: | Electronic |
Exhaust System | |
Exhaust Gas Flow | 1489L/s |
Exhaust Temperature | 532℃ |
Max Back Pressure | 10kPa |
Air Intake System | |
Max Intake Restriction | 6.23kPa |
Consumption | 533L/s |
Intake Flow | 9800 L/s |
Fuel System | |
100%( Prime Power) Loa | 204.6 g/Kw.h |
75%(Prime Power) Loa | 205.4 g/Kw.h |
50%(Prime Power) Load | 215.7 g/Kw.h |
100%( Prime Power) Loa | 92.4L/h |
Oil System | |
Total Oil Capacity | 50L |
Oil Consumption | ≤4g/kw |
Engine Oil Tank Capacity | 38L |
Oil Pressure at Rated RPM | 345-483kPa |
Cooling System | |
Total Coolant Capacity | 91L |
Thermostat: | 82-93℃ |
Max Water Temperature | 104℃ |
Alternator SpecifiCAT-parts-partsion
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data
Number of Phase: | 3 |
Connecting Type: | 3 Phase and 4 Wires, “Y” type connecting |
Number of Bearing: | 1 |
Power Factor: | 0.8 |
Protection Grade: | IP23 |
Altitude: | ≤1000m |
Exciter Type: | Brushless, self-exciting |
Insulation Class, Temperature Rise: | H/H |
Telephone Influence Factor (TIF): | <50 |
THF: | <2% |
Voltage Regulation, Steady State: | ≤±1% |
Alternator Capacity: | 500KVA |
Alternator Efficiencies: | 93.8% |
Air Cooling Flow: | 1.035m3/s |
|
|
Generating set data:
Voltage Regulation: | ≥±5% |
Voltage Regulation, Stead State: | ≤±1% |
Sudden Voltage Warp (100% Sudden Reduce): | ≤+25% |
Sudden Voltage Warp (Sudden Increase): | ≤-20% |
Voltage Stable Time (100% Sudden Reduce): | ≤6S |
Voltage Stable Time (Sudden Increase) | ≤6S |
Frequency Regulation, Stead State: | ≤5% |
Frequency Waving: | ≤0.5% |
Sudden Frequency Warp (100% Sudden Reduce): | ≤+12% |
Sudden Frequency Warp (Sudden Increase): | ≤-10% |
Frequency Recovery Time (100% Sudden Reduce): | ≤5S |
Frequency Recovery Time (Sudden Increase): | ≤5S |