Specifications
Place of Origin :
China OEM and UK
Brand Name :
GSKA
Model Number :
DSE704
Weight: :
0.25 kg
MOQ :
1-5 pieces
Price :
Negotiable
Packaging Details :
Standard plywood and wood package.the actual package size against goods size and handle requires. Si
Delivery Time :
one weeks on receipt of official sales contract
Payment Terms :
L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability :
500 pieces per Month
Port: :
HongKong or ShenZhen,ShangHai,Dalian as required
Package Size: :
125mm X 165mm X 28 mm
CertifiCAT-partsion :
CE/RoHs/ISO9001
Dimensions :
125*165*28mm
Description
  1. Model Number :DSE704
  2. Function : start and stop the engine and indiCAT-parts-partse fault conditions, automatically shutting down the engine and indiCAT-parts-partsing the engine failure by LED, giving true, first-up fault annunciation.
  3. LED indiCAT-parts-partsors
  4. Power Supply : 8 to 35 Vdc Continuous
  5. Alternator Input Range : Operating 50mA; Standby 10mA

We are authorized agent

Deep Sea Electronics PLC The DSE704 is an Automatic Mains Failure module with generator monitoring,

protection and start facilities. It utilises advanced surface mount construction techniques to provide a

compact yet highly specified module.

Operation of the module is via three pushbuttons mounted on the front panel with STOP, MANUAL and

AUTO positions. Selection of the ‘Auto’ mode is confirmed by LED indiCAT-parts-partsor, and monitors the incoming

mains supply (3 phase or single phase).

Should the incoming AC mains supply fall below a configurable pre-set limit (180V default), the generator

will be started, and load transferred to the gen-set.

When the AC mains supply returns to within limits, the module will wait for a configurable, pre-set

stabilisation period, and then transfer load back to the mains.

The engine will be instructed to stop after a cool-down period. The module’s microprocessor provides a

comprehensive list of timers and functions, and access to the settings is via a small Configuration Switch on

the rear of the module.

Parameter settings can be adjusted using the front panel pushbuttons once in Configuration Mode.

Main Features:

• Automatic mains (utility) supply monitoring
• Automatic shutdown when fault conditions are detected
• Manual start
• Engine pre-heat
• Engine monitoring and protection features
• Protected Solid State (PSS) outputs

• Front panel mounting

• Front panel programming

• Remote start

• LED indiCAT-parts-partsors

• Configurable timers

• Configurable outputs

• ransfers between mains (utility) and generator power

• On-site module configuration to match user requirements

• Multiple engine parameters are monitored simultaneously

Power Supply

8 to 35 Vdc Continuous

Cranking Dropouts:

Able to survive 0 V for 50 mS, providing supply was at least 10 V
before dropout and supply recovers to 5V. This is achieved without the need for internal batteries.

Max Current

Operating 50mA; Standby 10mA

Alternator Input Range

75(ph-N) to 277(ph-N) 3 Phase 4wire AC (+20%)

Alternator Input Frequency:

50 - 60 Hz at rated engine speed (Minimum: 75V AC Ph-N) (Crank
Disconnect from 15V Ph-N @ 20Hz) Overspeed +14% (+24% overshoot)
Underspeed –20%

Start Output:

1.2 Amp DC at supply voltage

Fuel Output:

1.2 Amp DC at supply voltage.

Auxiliary Outputs

1.2 Amp DC at supply voltage

Charge Fail

12V = 8V CF 24V = 16V CF

Operating Temperature Range:

-30 to +70°C

Dimensions: 125 X 165 X 28 mm

Send your message to this supplier
Send Now

DSE704 Deep Sea Control Panel , Automatic Mains Failure Module

Ask Latest Price
Place of Origin :
China OEM and UK
Brand Name :
GSKA
Model Number :
DSE704
Weight: :
0.25 kg
MOQ :
1-5 pieces
Price :
Negotiable
Contact Supplier
DSE704 Deep Sea Control Panel , Automatic Mains Failure Module

Guangdong ALI Testing Equipment Co,.Ltd

Active Member
13 Years
guangdong, dongguan
Since 1985
Business Type :
Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company
Total Annual :
4Million-5Million
Employee Number :
50~100
Certification Level :
Active Member
Contact Supplier
Submit Requirement