Liebert / Vertiv Emerson 6KVA/4800W Tower/Rack Mount UPS
ON LINE UPS Description
An Online UPS takes incoming power, converts it to DC, conditions it, and converts it back to AC. This means the UPS is Online since there is no delay to switch to battery. Use an online UPS for your critical appliCAT-parts-partsions, high availability servers, etc. The output of these online UPS systems are TRUE sine wave, and is usually better than power from the electric company.
How to choose the right UPS?
1. Understand specifiCAT-parts-partsions of all UPS.
2. Consider the requirements of power quality.
3. Understand the current capacity of UPS and consider the future expansion.
4. Choose UPS based on your requirements.
Function
1. Advanced DSP digital control technology
2 LCD+LED display
3. With output isolation transformer
4. DC cold start function
5. Frequency self- adaption
6. Special short circuit protection design
7. Support mobile phone smart monitoring card,real time monitoring UPS data through mobile APP.
SpecifiCAT-parts-partsion
Model | 10K | 15K | 20K | 30K | 40K | 60K | |||||||||||
Input | |||||||||||||||||
Rated voltage | 380VAC (Line voltage) /220VAC | ||||||||||||||||
Input wiring | 3Ø + N + E | ||||||||||||||||
Voltage range | (165±5~275±5)VAC | ||||||||||||||||
Bypass | |||||||||||||||||
Rated voltage | 380/220VAC | ||||||||||||||||
Voltage range | (165±5~275±5) VAC | ||||||||||||||||
Rated frequency | 50Hz/60Hz | ||||||||||||||||
Input power factor | 0.7 (185V,Linear full load ) | 0.75 (220V,Linear full load ) | |||||||||||||||
Output | |||||||||||||||||
Rated VA/Watt | 10KVA/ 8KW | 15KVA/ 12KW | 20KVA/ 16KW | 30KVA/ 24KW | 40KVA/ 32KW | 60KVA/ 48KW | |||||||||||
Rated voltage | 380VAC/220VAC | ||||||||||||||||
Output voltage range | 200/208/220/230/240VAC | ||||||||||||||||
Voltage regulation | ±2 % | ||||||||||||||||
THDV | ≤8 % | Full RCD load | |||||||||||||||
≤3 % | Linear full load | ||||||||||||||||
Output frequency range | |||||||||||||||||
Battery mode | (50+0.1) Hz/(60+0.1) Hz | ||||||||||||||||
Efficiency | |||||||||||||||||
Line mode | > 80% | > 80% | > 83% | > 88% | > 89% | > 90% | |||||||||||
Battery mode | > 85% | > 85% | > 88% | > 90% | > 0.92% | > 93% | |||||||||||
Transfer time | |||||||||||||||||
Line mode to Battery mode | 0mS | ||||||||||||||||
Battery mode to line mode | 0mS | ||||||||||||||||
Battery | |||||||||||||||||
Rated voltage | 192VDC | 384VDC | |||||||||||||||
Charge | |||||||||||||||||
Float charge voltage | (220±2)VDC | (440±2)VDC | |||||||||||||||
Charge time | Depending on the battery capacity | Depending on the battery capacity | |||||||||||||||
CommuniCAT-parts-partsion interface | |||||||||||||||||
RS232/ RS485 | Support | ||||||||||||||||
Intelligent slot | Support SNMP/AS400 | ||||||||||||||||
Environment | |||||||||||||||||
Working temperature | 0℃~40℃ | ||||||||||||||||
Work humidity | 20% ~ 95% | ||||||||||||||||
Safety | |||||||||||||||||
Safety | GB4943-2001/IEC62040-1 | ||||||||||||||||
Size(L*W*H) |
830*455* 1055 |
830*455* 1055 |
830*455* 1055 |
830*455* 1055 |
830*515* 1135 |
800*700* 1600 |
|||||||||||
Weight (KG) | 218 | 208 | 208 | 243 | 309 | 506.5 |