1KVA- 10KVA I50 Hz UPS Automatic Uninterruptible Power Supply
Model:Winner Pro 1K (L),Winner Pro 2K (L),Winner Pro 3K (L),Winner Pro 6K (L),Winner Pro 10K (L)
Description
Real online dual conversion
Microprocessor control ensures high reliability, input power factor correction function, output power factor up to 0.8, ultra wide power input range (110 V – 300 V) efficient frequency conversion mode eco mode can effectively save energy (only for 1-3k models) compatible with generator input
The optional intelligent SNMP card can monitor perfectly alone or together with USB and RS232. Through the display, it is easy to operate and control, and comprehensively display and monitor the ups status
Features
Type of machine | Winner Pro 1K (L) | Winner Pro 2K (L) | Winner Pro 3K (L) | Winner Pro 6K (L) | Winner Pro 10K (L) | |||||||
Phase | Single phase grounding | |||||||||||
Capacity * | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | 6000VA / 4800W | 10000 VA / 8000 W | |||||||
Input | ||||||||||||
Input Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 208/220/230/240VAC | ||||||||||
Voltage Range | 55-150 VAC or 110-300 VAC at 50% load 85-140VAC or 160-280VAC at 100% load |
110-300 VAC at 50% load 176-300 VAC at 100% load |
||||||||||
Frequency Range | 40 Hz ~ 70 Hz | 46~54 Hz 或 56~64 Hz | ||||||||||
Power factor | ≧ 0.99 @ 100% load | |||||||||||
Output | ||||||||||||
Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 208/220/230/240VAC | ||||||||||
Voltage stabilization accuracy (battery mode) | ± 1 % | |||||||||||
Frequency range (synchronous correction range) | 47~ 53 Hz or 57 ~ 63 Hz | 46~54 Hz or 56~64 Hz | ||||||||||
Frequency range (battery mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz or 60Hz ± 0.1 Hz | ||||||||||
Peak coefficient | 3:1 | |||||||||||
Harmonic distortion |
≦ 3 % THD (Linear load ) ≦ 6 % THD (Nonlinear load ) |
≦ 3 % THD (Linear load ) ≦ 5 % THD (Nonlinear load ) |
||||||||||
Conversation Time |
Mains to battery | Zero | ||||||||||
Inverter to bypass | 4 ms(Under standard conditions ) | None | ||||||||||
Waveform (battery mode) | Pure sine wave | |||||||||||
Efficiency | ||||||||||||
Utility mode | 88% | 88% | 90% | 92% | 93% | |||||||
Battery mode | 83% | 87% | 88% | 90% | 91% | |||||||
Battery | ||||||||||||
Stander machine |
Battery model | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 9 Ah | |||||||
Quandity | 2 | 4 | 6 | 16 | 20 | 16 | 20 | |||||
Standard charging time | Charge to 90% in 4 hours | Charge to 90% in 9 hours | ||||||||||
Maximum charging current | 1 A | 1 A / 2 A | ||||||||||
Charging voltage | 27.4VDC ± 1% | 54.7 VDC ±1% | 82.1 VDC ±1% | 218.4 VDC ±1% | 273 VDC ±1% | 218.4 VDC ±1% | 273 VDC ±1% | |||||
Long acting machine |
Battery model | Depends on the applicant | ||||||||||
Quandity | 2 | 3 | 4 | 6 | 8 | 6 | 8 | 16 ~ 20 (Adjustable ) | ||||
Maximum charging current | 1A/2A/4A/6A (Adjustable ) | 1A/2A/4A/6A (Adjustable , 6A only works with 16 batteries ) | ||||||||||
Maximum charging current | 27.4VDC ± 1% | 41.0VDC ± 1% | 54.7 VDC ±1% | 82.1 VDC ±1% | 109.4VDC ±1% | 82.1 VDC ±1% | 109.4VDC ±1% | 273 VDC ± 1%(basic on 20 pieces) | ||||
Display description | ||||||||||||
LCD | Load size, battery capacity, utility mode, battery mode, bypass mode, fault indiCAT-parts-partsion | |||||||||||
Warning sound | ||||||||||||
Battery mode | It rings every 4 seconds | |||||||||||
Low battery | It rings every second | |||||||||||
Overload | It rings every second | |||||||||||
Fault | Continuous sound | |||||||||||
Physical Property | ||||||||||||
Stander machine | Dimension, D*W*H(mm) | 282 x 145 x 220 | 397 x 145 x 220 | 421 x 190 x 318 | 369 x 190 x 688 | 442 x 190 x 688 | ||||||
Net Weight (KG) | 9.8 | 17 | 27.6 | 61 | 74 | 66 | 76 | |||||
Long acting machine | Dimension, D*W*H(mm) | 282 x 145 x 220 | 397 x 145 x 220 | 369 x 190 x 318 | 442 x 190 x 318 | |||||||
Net Weight (KG) | 4.1 | 6.8 | 7.4 | 12 | 16 | |||||||
Usage environment | ||||||||||||
Humidity | 20-90 % RH @ 0- 40°C (No condensation) | Relative humidity 0-95% & temperature 0-50 ° C (no condensation) | Relative humidity 0-95% & temperature0-40 ° C (no condensation) | |||||||||
Noise | Less than 50dba @ 1m | Less than 50dba @ 1m | Less than 50dba @ 1m | |||||||||
Control management | ||||||||||||
ntelligent RS-232 / optional USB | Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux & MAC | |||||||||||
Optional SNMP | Power management supports SNMP management and network management |
● Advanced dual-core DSP control technology and 3-level technology