Electricity Power 100kva Cummins diesel generator 80kw Genset 6bt5.9-g2 engine noise proof
Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm system and
arrestor for any situation as the start defeat, the water is over temperature, the oil
pulls down, over speed, over load and over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
2) Supply standard collocation:
a) Diesel engine with all accessories, 3 filter, electric systems
b) Alternator
c) Steel structure
d) Fan and water tank cooling system
e) Flange connector
f) 12 / 24V starting motor and charge engine
g) Air cleaner, fuel cleaner, oil cleaner
h) On-board control panel
i) MCCB air conservation switch
j) 12 / 24V starting accumulator and battery line
k) Set shock absorber
l) High-efficient silencer
1) Main Specification
a,3-Phase, 50Hz@1500RPM, 380/220V
b,Composed Cummins diesel engine and Stamford or Leroy Somer alternator
c,12V/24V DC start motor and storage battery
d,Brushless, Self-excited, IP23, insulation class H alternator
e, 40°C radiator as standard, 50°C is optional
f,Key start panel control system as standard, digital auto-start panel is optional
g,10-hour operation base tank
h,All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load, 110% load and all protection function (overspeed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
2) Data of generador diesel 100 kva
Prime Power | 80kw/100kva | Standby Power | 88kw/110kva |
Rated Speed | 1500rpm | Output Frequency | 50hz/60hz |
Phase | 3 | Rated Voltage | 400v |
Engine Brand | Cummins | Alternator Brand | Stamford |
Fuel Consumption | 20L | Fuel Tank capacity | 8 hours |
Voltage Regulation Rate | ≤±1% | Random Voltage Rate | ≤±1% |
Frequency Regulation Rate | ≤±5% | Random Frequency Variation | ≤±0.5% |
3) Engine Specificatio
Model | Cummins engine 6BT5.9-G2 |
Cooing Method | Forced water cooling |
Rotating speed | 1500/1800rpm |
Governor system | electrical or mechanical governor |
Aspiration mode | natural aspirated or turbocharged |
Starting method | 12/24V DC electric starting |
Stroke | 4 stroke |
4) Alternator Specification
Alternator Brand | China Stamford,LeroySomer, Marathon |
Exciter Type | Brushless, Self-excited |
Rated Speed | 1500/1800rpm |
Rated Frequency | 50/60hz |
Phase | three or single |
Rated Voltage | 400V (Available with customer requirements) |
Power | 0.8 |
Voltage Adjust Range | ≥5% |
Protection Grade | IP23 |
Insulation Grade | H |
5) Control System
Our standard genset controller provides functions,
a),Start/Stop controller
b),Ampere meter
c),Voltmeter and selector switch
d),Frequency meter/ Water temperature gauge/Oil pressure gauge/Hour counter/Battery voltage meter
e),Emergency stop pushbutton
f),Alarm System: Over speed, High Engine Temperature, Low Oil Pressure, Charge Fail
g),Protection System: Over speed, High Engine Temperature, Low Oil Pressure,Emergency Stop, and the other protection function pre-setting
h),AMF
i),ATS.