Soundproof 30kva Perkins Genset Diesel Generator with engine 1103A - 33G power Synchronous
The 30kva perkins genset adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set .
1. SPECIFICATIONS OF GEN-SET | ||
1.1 | Set Model | GNRP24 |
1.2 | Prime at 50HZ, 40°C ambient | 24KW 30KVA |
1.3 | Standby at 50HZ, 40°C ambient | 26KW 33KVA |
1.4 | Rated Gen-set output | 230/400V 50Hz |
1.5 | Rated Relative humidity | ≤ 60 % |
1.6 | Dimension (L×W×H) | 2000×850×1150mm |
1.7 | Weight | 1100kg |
1.8 | Fuel consumption 100% prime load | 7,8 l/hr |
1.10 | Structure of Gen-set | The Gen-set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set |
1.11 | Control system (Optional) | Basic control panel or Advanced control panel with automatically start-up function and other function |
2. SPECIFICATIONS OF ENGINE | ||
2.1 | Engine Brand | Perkins |
2.2 | Engine Model | 1103A-33G |
2.3 | Governor/Class | Mechanical |
2.4 | Cylinder NO. | 3 |
2.5 | Engine build | Vertical in-line |
2.6 | Fuel spray pattern | direct injection |
2.7 | Aspiration | Naturally |
2.8 | Cooling mode | Radiator cooled (enclose water) |
2.9 | Bore and stroke | 105×127mm |
2.10 | Compression ratio | 19.25 : 1 |
2.11 | Displacement | 3.3L |
2.12 | Engine Prime Power at 1500rpm | 27KWm |
2.13 | Engine Standby Power at 1500rpm | 30KWm |
2.14 | Start-up mode | 12V, electric |
2.17 | Lubricating oil consumption | Lubricating oil consumption less than 10% Fuel consumption |
2.18 | Lubrication oil capacity | 7.0litres |
2.19 | Coolant capacity – radiator and engine (40°C) | 10.2litres |
2.20 | Exhaust temp – full load prime | 515°C |
2.21 | Exhaust gas flow – full load prime | 6.1m³/min |
2.22 | Exhaust gas back pressure max | 15 kPa |
2.25 | Air intake – engine– full load prime | 2.6m³/min |
2.26 | Standard Air intake temp | 25°C |
2.27 | Fuel type | #0 Diesel (Natural temperature) |
2.28 | Filter system | Adopt whole changeable lubricating oil, fuel filter and air filter |
2.29 | Exhaust system | Adopt industrial high efficiency silencer and flexible bellows |
3. SPECIFICATIONS OF ALTENATOR | ||
3.2 | Alternator Type | A.C. Synchronous |
3.3 | Rated Voltage | 230/400V |
3.4 | Rated Frequency | 50HZ |
3.5 | Rated speed | 1500 RPM |
3.6 | Voltage regulation mode | Auto |
3.7 | Alternator voltage regulation | ±0.5% |
3.8 | Exciting mode | Brushless self exciting |
3.9 | Power factor | 0.8 (lagging) |
3.10 | Phase & wires | 3 phase 12 wires |
3.11 | Rated currency | 45A |
3.12 | Efficiency | 0.862 |
3.13 | Insulation class | H |
3.14 | Protection class | IP23 |
3.15 | Single load step to NFPA110 | 100% |
3.16 | Standards | IEC34-1 |
3.17 | Max. Ambient Temperature | 40°C |
3.18 | Min. Ambient Temperature | - 20°C |
3.19 | Max. altitude | 1000m |
3.20 | Weight | 237Kg |