SDEC Genset 80kw 100kva Silent Open Easy Maintenance Diesel Generator
Overview
Application field
● Industrial field: widely used in industrial and mining enterprises to provide stable power for production equipment, such as mining, factory production and other scenarios.
● Commercial field: Commercial buildings such as shopping malls, hotels, office buildings, etc., in the case of power failure, diesel generators can be used as backup power to ensure basic operations.
● Public utilities: hospitals, schools, communication base stations and other public facilities need reliable power supply, and diesel generators can provide power support in emergency situations.
advantage
● Advanced technology: The use of electronic control high pressure common rail fuel injection system and other advanced technology, effectively reduce fuel consumption and harmful gas emissions, improve combustion efficiency.
● Easy maintenance: optimized design of lubrication, cooling system and overall brushless alternator, reducing the number of external pipes and parts, reducing maintenance costs and difficulties.
● High degree of intelligence: equipped with automatic controller, can monitor the operating status of the unit in real time, with water high temperature, low oil pressure, over current, over load and other protection functions, can also achieve remote monitoring and fault diagnosis.
SDEC GEN-SETS DATASHEET RATED80kW | ||||||
Gen-set specifications | ||||||
Model | JW-D80S3K-1 | |||||
Standby Rating kVA/kWe | 110/88 | |||||
Prime Rating kVAkWe | 100/80 | |||||
Voltage V | 400/230 | |||||
Frequency Hz | 50 | |||||
Power Factor | 0.8(lagging) | |||||
No.of Phases | 3 | |||||
Fuel consumption@25%/50%175%(L/h)75%(L/h) | 6.5/11.8/17.1 | |||||
Fuel consumption@100%/110%(L/h) | 23.0/25.9 | |||||
Sound@1m(dB · (A)) | Open≤96;Silence ≤90 | |||||
Emission level | Non-Road China ll | |||||
Ambient temp(℃) | 5~45 | |||||
Gen-set regulation class | ISO 8528-5 G2 | |||||
Steady-state voltage deviation | ≤±2.5% | |||||
Transient voltage deviation (100%sudden power decrease/increase) | ≤+25%;≤-20% | |||||
Steady-state frequency band | ≤1.5% | |||||
Gen-set regulation class | ≤+12%;≤-10% | |||||
Standard | ||||||
◆Electronic governor | ◆DC24 Electric starter | ◆JW-SDEC6110N | ||||
◆Closed water-cooled | ◆IP22 | ◆H type insulation | ||||
◆Air filter | ◆Metal bowl shock absorbers | ◆Circuit Breaker | ||||
◆Startingbatteries+connective wires+ Negative switch | ◆Radiator | ◆Charger | ||||
◆Oil Drain plugs | ◆Base fuel tank and low noise forklift hole | ◆Random files | ||||
◆Color:Gray-black(open type)/White(low noise) | ||||||
◆Packaging:Wound film packing | ||||||
Options | ||||||
◇ Line Voltage380V/415V | ◇ Line Voltage 440V/480V | ◇ Voltage 6.3kV/10.5kV/13.8kV | ||||
◇ Single Voltage 220V/230V | ◇ Automatic Transfer Switch | ◇ Automatic Parallel system | ||||
◇ Engine Heater(water/fuel) | ◇ Oil heating | ◇ Alternator heater | ||||
◇ External fuel tank(1000L) | ◇ AREP | ◇ PMG | ||||
◇ Muffler | ◇ Black smoke purification device | ◇ Cloud monitoring |