Specifications
Brand Name :
HICORPWELL
Model Number :
HCW-325 Fiber Optic Visual Fault Detector
Certification :
IEC 60794-2-10/11
Place of Origin :
China
MOQ :
1pcs
Price :
negotiation
Payment Terms :
Western Union, L/C, T/T
Supply Ability :
1000pcs Per Week
Packaging Details :
HCW-325 Packages :25 x 195mm,Weight 165g (without battery)Dimension25 x 195mm
Item No :
HCW-325 50MW High Voltage Cable Fault Locator
Packages Size :
25 x 195mm 165g (without battery)
Package :
Black Leather Sheath And White Box
battery Type :
LR6 AA alkaline battery
Optical connectorFull Name :
2.5mm universal connector
1.25mm connectors, FC (Male)-LC. (Female) convertor can be provided on request :
FC(Male)-LC. (Female) convertor can be provided on request
Description

Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification

Method of Using :

1. Screw the end cap from the pen, the battery will be prepared into the pen, battery cathode to the end cap, the positive on the pen body is positive;(note: please do not turn pen and pencil tail into the battery)


2. Put the pen and pencil body connection installed, open the dust cap, press the control switch one time, observe the interface has a red light, luminous tube on at the same time;(note don't eyes were light interface, so as not to damage the eye)


3. Press the control switch again, observe the light into a pulse mode, the indicator light-emitting tube and out of sync pulse light;(pulse frequency in 2-3 hz or 9 hz)


4. Press the control switch again, light source closed, no light output, at the same time indicator light pipe out;(switch mode to: continuous - pulse - closed - continuous cycle mode)


5. When detecting insert tested optical fiber optical interface, press the control switch at the same time, choose the output light work mode (continuous or pulse);


6. After use, build the dust cap, do not use for a long time, please take out the battery, in order to avoid battery rot, damage the light source.

Maintenance and matters needing attention

1. Laser and harmful, especially to pay attention to protect the eyes, when laser works, avoid to irradiate the eyes with laser directly;
2. In generally, the higher the temperature, the shorter the life of laser, when used to avoid high temperature working environment;

3. The work of laser optical fiber head should be cleaned;

4. When used, the optical interface and the interface needs to detect light and light pull plug;

5. Don't use the light source, would you please put dust cap to avoid dust fall;

6. Should remove the battery when not in using;

7. Please do not remove the end cap and any part of the dust cap, remove shall not be responsible for damage caused.Fiber Checker Fiber Tester Tools Optic Visual Fault Detector network fiber checker fiber optic visual fault detector

ModelHCW-325
Central wavelength650nm±10nm (635nm is available on request)
Emitter typeFP-LD
Output power50MW
Laser Range≥50km
Optical connector2.5mm universal connector, for 1.25mm connectors, FC (Male)-LC. (Female) convertor can be provided on request
Operating modeBoth CW and Pulse available
Pulse frequency2Hz to 3Hz / 9Hz
Power supply2AA alkaline batteries
Battery LR6 AA alkaline battery
Operating temperature-20°C to 60°C
Storage temperature-40°C to 85°C
Dimension25 x 195mm
Weight165g (without battery)



Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault IdentificationFiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault IdentificationFiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault IdentificationFiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification













Send your message to this supplier
Send Now

Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification

Ask Latest Price
Watch Video
Brand Name :
HICORPWELL
Model Number :
HCW-325 Fiber Optic Visual Fault Detector
Certification :
IEC 60794-2-10/11
Place of Origin :
China
MOQ :
1pcs
Price :
negotiation
Contact Supplier
video
Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification
Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification
Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification
Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification
Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification

Shenzhen Hicorpwell Technology Co., Ltd

Site Member
8 Years
guangdong, shenzhen
Since 2013
Business Type :
Manufacturer, Importer, Exporter
Total Annual :
3,000,000-5,000,000
Employee Number :
160~166
Certification Level :
Site Member
Contact Supplier
Submit Requirement