Wireless BLE All-in-One Ultrasonic Fuel Level Sensor for Fleet Fuel Monitoring/Telematics
Features & Specification:
Part No. | Maximum Range | Blind Area | Beam Range | BLE Bluetooth | Signal Output | Voltage | |
UL212 | 100 cm | 3cm | 11° | Yes | RS232/RS485, Analogue (0~5V) | 9~36V | |
UL212-E | 250 cm | 3cm | 11° | Yes | RS232/RS485, Analogue (0~5V) | 9~36V | |
With the ultrasonic reflection feature when cross liquid to air, it can read accurate fuel level height.
Parameter | Description |
Power Supply | 9~36V DC |
Max Power Consumption | 0.7W @12V DC |
Measuring Range | 3~250cm |
Resolution | 0.1mm |
Accuracy | 99.5% (0# Diesel ,25℃) |
Maximum Tank Thickness | <12mm |
Interface | RS232(default)/RS485 Analog 0~5V BLE Bluetooth5.0 CAN (optional) |
Serial Communication | 9600 baud rate(customized),data bit 8, stop bit1, no flow control,no verification bit |
Support Protocols | Teltonika, GEOTAB, BCE, Ruptela, Ominicomm LLS, CR, Calamp, Atrack, Fifotrack, Queclink, Meitrack, Concox Jimi, Queclink, Xirgo,Wireless Link |
Extension Cable | 9 meters |
Working Temperature | -40~85℃ (@1 ATM) |
Working Humid | 5~99% |
Explosion-proof Class | Exd II CT5 |
Waterproof | IP68 |
| Power Supply 9~36V DC+ | |
| Power GND, RS232/RS485 GND | |
| RS232 TX (Default), or RS485B | Connect GPS/DVR RS232_RX, Or RS485B |
| RS232 RX (Default), or RS485A | Connect GPS/DVR RS232_TX, Or RS485B |
| Analog Output 0~5V |
Recommended GPS Tracker that can work with our ultrasonic fuel sensor:
1 Meter Version, TSULS212
Part Number | Protocol Description/Complied Hardware | | | Baud Rate | |
| Standard Protocol: Calamp,Atrack, Fifotrack, Wireless Link,etc. | | RS232 or RS485 Analog 0~5V | | |
| Private Protocol with Fuel Theft I/O Alarm Output (Green Cable, 5V) | | RS232 or RS485 | | Support Fuel Theft Alarm |
| Private Protocol with Volume & Height Output at the same time, with Fuel Theft I/O Alarm Output (Green Cable , 5V) | | RS232 or RS485 | |
|
| | | RS232 or RS485 Analog 0~5V | | |
| Omonicomm LLS protocol, Eurosens, Example: 3E 01 07 14 DC 04 DC 04 67 | | RS232 or RS485 Analog 0~5V | | Net Address 1 |
| | | RS232 or RS485 Analog 0~5V | | Net Address 2 |
| | | RS232 or RS485 Analog 0~5V | | Net Address 1 |
| GEOTAB | | Analog 0~5V | | Programmable Full Tank Height |
| CR Protocol: Icarvision, BSJ *CFV01001A3DF3 | | | | Net Address 1 |
| Modbus Protocol | | RS232 or RS485 | ||
| | | Analog 0~5V | | Net Address 1 |
2.5 Meter Version, TSULS212-E