This equipment is designed for filling automobile shock absorber assembly with nitrogen. This
equipment consists mainly of a hydraulic clamping system, an inflatable system, and an electronic control
system. The electronic control system uses a touch screen for operation and configuration, which is user-
friendly and intuitive. It is equipped with a pressure sensor to detect the rebuttal force value of the inflated
product and an alarm. If the force value of a product exceeds a certain range, an alarm will be triggered. This equipment can automatically position the detection head to the required position according to the requirements of the product's refractory force detection position.
S/N |
Item |
Parameter |
Remarks |
1 | Reservoir diameter φ D | φ30 ~ φ65mm | |
2 | Connecting rod diameter φ d | φ10 ~ φ28mm | |
3 | Tank assembly height L | 250~500mm | |
4 | Link extension length L2 | ≤420mm | |
5 | Filling gas pressure | <1.5MPa | |
6 | Pressure sensor range | 5kN | |
Pressure detection accuracy | ±5N |